background image

English

5

9. Display 

 (inspection/test operation)

When the inspection/test operation button is 
pressed, the display shows the mode in which 
the system actually is. (For servicing only)

10. Display 

 (under centralized control)

When this display shows, the system is under 
centralized control. (This is not a standard spec-
ification.)

11. Display 

 (fan speed)

This display shows the fan speed you have 
selected.

12. Display 

 (time to clean air filter)

Refer to the operation manual of indoor unit.

13. Display 

 (defrost/hot start)

Refer to the chapter “Operation procedure - 
Explanation of heating operation.”

14. Timer mode start/stop button

Refer to the chapter “Operation procedure - 
Programming start and stop of the system with 
timer.”

15. Timer on/off button

Refer to the chapter “Operation procedure - 
Programming start and stop of the system with 
timer.”

16. Inspection/test operation button

This button is only used by qualified service 
persons for maintenance purposes.

17. Programming time button

Use this button for setting the programming start 
and/or stop time.

18. Temperature setting button

Use this button for setting the desired temperature.

19. Filter sign reset button

Refer to the operation manual of indoor unit.

20. Fan speed control button

Press this button to select the fan speed of your 
preference.

21. Operation mode selector button

Press this button to select the operation mode of 
your preference.

22. Air flow direction adjust button

Refer to the chapter “Operation procedure - 
Adjusting the air flow direction”.

23. Fan only/air conditioning selector switch

Set the switch to “

” for fan only operation or to 

” for heating or cooling operation.

24. Cool/heat changeover switch

Set the switch to “

” for cooling operation or to 

” for heating operation.

25. Thermistor

It senses the room temperature around the 
remote controller.

26. These button are used when the total heat 

exchanger unit (Heat Reclaim Ventilation) are 
installed. (These are optional accessories.)

Refer to the operation manual of the total heat 
exchanger unit (Heat Reclaim Ventilation).

27. No function display

• If a function is not available in the indoor unit 

even if the button is pressed, “NOT AVAIL-
ABLE” is may be displayed for a few seconds.

• When using multiple units at the same time.

“NOT AVAILABLE” is only displayed when 
none of the indoor units is equipped with that 
function.
If even one of the indoor units has the function, 
it will not be displayed.

NOTE

• In contradistinction to actual operating situations, 

the display on figure 2 shows all possible indica-
tions.

• Figure 2 shows the remote controller which is 

opened the cover.

• The remote controller BRC1A52 

(for FXS, FXM, FXL, FXN) does not have the dis-
play air flow flap (4) nor the air flow direction 
adjust button (22).

5. OPERATION RANGE

*This value shows a quantity of water per one out-

side unit.

NOTE

To avoid condensation and water dripping out the unit.
If the temperature or the humidity is beyond these 
conditions, safety devices may work and the air condi-
tioner may not operate.

TEST

COOLING

HEATING

Ambient temperature 
around the outside unit

0°~40°C

Ambient humidity around 
the outside unit

 80%

indoor temperature

21°~32°C

15°~27°C

Water temperature at the 
inlet of the outside unit

10°~45°C

Water volume in the out-
side unit

50~150L/min*

01_EN_3P153897-7L.fm  Page 5  Friday, July 11, 2008  1:58 PM

Содержание VRV-WIII RWEYQ8PY1

Страница 1: ...ystem air conditioner Betriebsanweisung VRVWIII System Klimaanlage Manuel d utilisation Conditionneur d air VRVWIII System Manual de operaci n Sistema de acondicionador de aire VRVWIII Manuale d uso C...

Страница 2: ...as referencias Asimismo si lo desea puede consultar detalles sobre la unidad interior en el manual de funcionamiento pro vistoconlamisma Guardeel manualdefuncionamientoconlaunidad interior y con este...

Страница 3: ...1 4 3 NOT AVAILABLE 2 5 6...

Страница 4: ...8 7 1 7 2 7 3 Double flow Ceiling Suspended Wall Mounted Multi flow Corner 13 9 10 11 12 14 Heat pump system Heat recovery system...

Страница 5: ...to it whenever neces sary If the equipment is transferred to a new user be sure also to hand over the manual WARNING Be aware that prolonged direct exposure to cool or warm air from the air conditione...

Страница 6: ...solvents such as paint thinner The use of organic solvents may cause crack dam age to the product electric shocks or fire Be sure to use a dedicated power supply for the air conditioner The use of any...

Страница 7: ...bout checking and adjustment of internal parts Do not leave the remote controller wherever there is a risk of wetting If water gets into the remote controller there is a risk of electrical leakage and...

Страница 8: ...e air flow direction 5 Display ventilation air cleaning This display shows that the total heat exchanger unit Heat Reclaim Ventilation are in operation these are optional accessories 6 Display set tem...

Страница 9: ...ditioning selector switch Set the switch to for fan only operation or to for heating or cooling operation 24 Cool heat changeover switch Set the switch to for cooling operation or to for heating opera...

Страница 10: ...eration mode cool heat changeover is automatically performed Press the on off button The operation lamp lights up and the system starts operation FOR SYSTEMS WITH COOL HEAT SELECTOR Refer to figure 4...

Страница 11: ...ing operation mode with the Cool Heat selector Press the operation mode selector button sev eral times and select program dry Press the on off button The operation lamp lights up and the system starts...

Страница 12: ...hown in figure 14 it is necessary to designate one of the remote con trollers as the master remote controller Only the master remote controller can select heating automatic or cooling operation The di...

Страница 13: ...he air blow directly to a person Make sure that the inlet and outlet of the indoor unit are not clogged 8 MAINTENANCE 8 1 HANDLING OF HEAT SOURCE WATER Requests from manufacturer Do not fail to mount...

Страница 14: ...e the remote control is intercepting noise from electrical appliances other than the air conditioner and this prevents communication between the units causing them to stop Operation automatically rest...

Страница 15: ...A hissing sound which is heard at the start or immediately after stopping operation This is the noise of refrigerant gas caused by flow stop or flow change 9 9 DUST COMES OUT OF THE UNIT When the uni...

Страница 16: ...r failure Wait until power is restored If power failure occurs during operation the system automatically restarts immediately after the power supply is recovered Check if no fuse has blown Turn off th...

Страница 17: ...comes in contact with the combustible air in the equipment such as fan heater stove oil gas cooker etc it will cause toxic gas to be generated When a refrigerant leakage failure has been repaired conf...

Страница 18: ...ection fees etc Depending on the content of the maintenance and inspection contract the inspection and maintenance cycles may in reality be shorter than those listed here Shortening of maintenance cyc...

Страница 19: ...d the refrigerant in accordance with chlorofluoro carbon collection and destruction law Where to call For after sales service etc consult with your dealer Warranty period This product includes a warra...

Страница 20: ...3P153897 7L EM08A054 0808 HT...

Отзывы: