• The movable limit of the flap is changeable.
Contact your Daikin dealer for details. (Only
for FXC, FXF, FXH, FXK, FXA.)
• Avoid operating in the horizontal direction
“
”. It may cause dew or dust to settle on
the ceiling.
6-4
PROGRAMMING START AND STOP
OF THE SYSTEM WITH TIMER
(Refer to figure 9)
• The timer is operated in the following two
ways.
Programming the stop time “
”. The
system stops operating after the set time
has elapsed.
Programming the start time “
”. The
system starts operating after the set time
has elapsed.
• The timer can be programmed for a maxi-
mum of 72 hours.
• The start and the stop time can be simulta-
neously programmed.
Press the timer mode start/stop button several
times and select the mode on the display.
The display flashes.
• For setting the timer stop “
”
• For setting the timer start “
”
Press the programming time button and set
the time for stopping or starting the system.
Each time this button is pressed, the
time advances or goes backward by
1 hour.
Press the timer on/off button.
The timer setting procedure ends. The display
“
” or “
” changes from flashing
light to constant light.
NOTE
• When setting the timer off and on at the
same time, repeat the above procedure
(from “
” to “
”) once again.
• After the timer is programmed, the display
shows the remaining time.
• Press the timer on/off button once again to
cancel programming. The display vanishes.
For example: (Refer to figure 11)
When the timer is programmed to stop the sys-
tem after 3 hours and start the system after
4 hours, the system will stop after 3 hours and
start 1 hour later.
6-5
SETTING THE MASTER REMOTE
CONTROLLER (Refer to figure 10)
• When one outside unit or BS unit is connected
with several indoor units as shown in figure 14, it
is necessary to designate one of the remote con-
trollers as the master remote controller.
• Only the master remote controller can select
heating, automatic or cooling operation.
• The displays of slave remote controllers show
“
” (changeover under control) and they
automatically follow the operation mode directed
by the master remote controller.
However, it is possible to changeover to program
dry with slave remote controllers if the system is in
cooling operation by setting on the master remote
controller and to changeover to fan only opera-
tion.
How to designate the master remote controller
Press the operation mode selector button of
the current master remote controller for 4 sec-
onds.
The display showing “
” (changeover
under control) of all slave remote controllers
connected to the same outside unit flashes.
Press the operation mode selector button of
the controller that you wish to designate as the
master remote controller. Then designation is
completed. This remote controller is desig-
nated as the master remote controller and the
display showing “
” (changeover
under control) vanishes.
The displays of other remote controllers show
“
” (changeover under control).
6-6
PRECAUTIONS FOR GROUP CON-
TROL SYSTEM OR TWO REMOTE
CONTROLLER CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller con-
trols one indoor unit) system. Confirm about your
system to Daikin dealer.
•
Group control system
One remote controller controls up to 16 indoor
units. All indoor units are equally set.
•
Two remote controllers control system
Two remote controllers control one indoor unit (in
case of group control system, one group of indoor
units). The unit is individually operated.
NOTE
• Contact your Daikin dealer in case of chang-
ing the combination or setting of group con-
trol and two remote controller control
systems.
1
2
3
1
3
1
2
01_EN_3P153897-7L.fm Page 8 Friday, July 11, 2008 1:58 PM
Содержание VRV-WIII RWEYQ8PY1
Страница 3: ...1 4 3 NOT AVAILABLE 2 5 6...
Страница 20: ...3P153897 7L EM08A054 0808 HT...