background image

 

Operation manual

 

1

 

HXHD125A8V1B

 

VRV IV system indoor unit

 

4P404572-1 – 2015.04

 

C

 

ONTENTS

 

Page

 

1.

Definitions.................................................................................. 1

 

1.1.

Meaning of warnings and symbols................................................. 1

1.2.

Meaning of used terms .................................................................. 1

 

2.

General safety precautions........................................................ 2

3.

Introduction................................................................................ 2

 

3.1.

General information........................................................................ 2

3.2.

Scope of this manual ..................................................................... 2

 

4.

Quick start-up of the unit ........................................................... 3

 

Space heating operation ................................................................ 3
Domestic water heating operation.................................................. 3

 

5.

Operation of the unit .................................................................. 4

 

5.1.

Remote controller buttons and icons.............................................. 4

5.2.

Setting the clock............................................................................. 5

5.3.

Space heating operation (

 

).......................................................... 6

Room temperature control ............................................................. 6
Leaving water temperature control................................................. 7

5.4.

Domestic water heating operation (

 

) .......................................... 8

Automatic storage .......................................................................... 8
Manual storage .............................................................................. 9
Reheat ......................................................................................... 10
Disinfection operation................................................................... 10

5.5.

Other operation modes ................................................................ 10
Start up operation (

 

) ........................................................... 10

Defrost operation (

 

) ............................................................ 10

Quiet mode operation (

 

) .......................................................... 10

5.6.

Simultaneous demand of space heating and domestic water 
heating ......................................................................................... 11

5.7.

Temperature read-out mode......................................................... 11

5.8.

Schedule timer operation ............................................................. 11
Space heating .............................................................................. 11
Domestic water heating................................................................ 13
Quiet mode .................................................................................. 13

5.9.

Programming and consulting the schedule timer ......................... 13
Programming space heating ........................................................ 14
Programming domestic water heating.......................................... 15
Programming quiet mode............................................................. 16
Consulting programmed actions .................................................. 17
Tips and tricks .............................................................................. 17

5.10. Operating the remote alarm option .............................................. 17
5.11. Operating the optional remote controller...................................... 17
5.12. Field settings ................................................................................ 18

Procedure .................................................................................... 18

5.13. Field settings table ....................................................................... 19

 

6.

Maintenance ............................................................................ 21

 

6.1.

Maintenance activities.................................................................. 21

6.2.

Important information regarding the refrigerant used................... 21

 

7.

Troubleshooting ....................................................................... 21

 

Thank you for purchasing this unit.

The original instructions are written in English. All other languages
are translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children shall be supervised to ensure that they do not play with the
appliance.

 

1. D

 

EFINITIONS

 

1.1.

Meaning of warnings and symbols

 

Warnings in this manual are classified according to their severity and
probability of occurrence.

Some types of danger are represented by special symbols:

 

1.2.

Meaning of used terms

 

Installation manual:

 

Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.

 

Operation manual:

 

Instruction manual specified for a certain product or application,
explaining how to operate it.

 

Maintenance instructions:

 

Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.

 

Dealer:

 

Sales distributor for products as per the subject of this manual.

 

Installer:

 

Technical skilled person who is qualified to install products as per the
subject of this manual.

 

HXHD125A8V1B

 

VRV IV system indoor unit

 

Operation manual

 

CAREFULLY READ THESE INSTRUCTIONS BEFORE
OPERATING THE UNIT. THEY WILL TELL YOU HOW TO
USE THE UNIT PROPERLY. KEEP THIS MANUAL IN A
HANDY PLACE FOR FUTURE REFERENCE.

 

CAUTION

 

 

This unit contains electrical and hot parts.

 

 

Before operating the unit, be sure the installation has
been carried out correctly by an installer.
If you feel unsure about operation, contact your
installer for advice and information.

 

DANGER

 

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

 

WARNING

 

Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

 

CAUTION

 

Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.

 

NOTICE

 

Indicates situations that may result in equipment or
property-damage accidents only.

 

INFORMATION

 

This symbol identifies useful tips or additional information.

 

Electric current.

 

Danger of burning and scalding.

Содержание VRV IV HXHD125A8V1B

Страница 1: ...OPERATION MANUAL HXHD125A8V1B system indoor unit...

Страница 2: ...by a person responsible for their safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS 1 1 Meaning of warnings and symbols Warnings in this manual are...

Страница 3: ...Scope of this manual This manual describes how to start up and switch off the unit set parameters and configure the schedule timer by means of the controller maintain the unit and solve operational p...

Страница 4: ...l light up and the unit will start For further details and advised settings see 5 3 Space heating operation on page 6 Domestic water heating only if domestic hot water tank option is installed Automat...

Страница 5: ...the current temperature of the installation either leaving water set point temperature or actual room temperature When changing the room temperature set point the set point will be flashing for 5 seco...

Страница 6: ...the indoor unit outdoor ambient temperature actual room temperature and domestic hot water temperature and in schedule timer programming mode 29 LEAVING WATER TEMPERATURE ADJUST BUTTONS and These but...

Страница 7: ...back function can for instance be activated during the night because the temperature demands during night and day are not the same The setback function is configured through field settings Refer to th...

Страница 8: ...Press the button 1 time to select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon appears on the display as well as the shift value Th...

Страница 9: ...ight when space heating requirements are lower until the storage temperature set point is reached The heated water is stored in the domestic hot water tank at a higher temperature so it can fulfil the...

Страница 10: ...igher too so that storage temperature set point can be set lower in order to keep the overall equivalent hot water amount the same during the whole year Therefor it is recommended to use this function...

Страница 11: ...tting 4 00 is set to ON 5 5 Other operation modes Start up operation During start up the icon displays indicating that the heat pump is starting up and is not working in a steady state condition Defro...

Страница 12: ...n is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressin...

Страница 13: ...nd will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command...

Страница 14: ...out the form at the very end of this manual This form can help you define the required actions for each day Take your time to enter all data accurately Try to program the actions in a chronological w...

Страница 15: ...and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the a...

Страница 16: ...button to select the action number you would like to program or to modify 8 Use the and buttons to set the correct action time 9 Use the button to select or deselect as action 10 Repeat steps 7 to 9...

Страница 17: ...odify 7 Use the and buttons to set the correct action time 8 Use the button to select or deselect as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions hav...

Страница 18: ...o step 2 by pressing the button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day...

Страница 19: ...The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button to select the appropriate field setting first code 3 Press the button to select th...

Страница 20: ...mperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri M...

Страница 21: ...icable Do not change the default value 20 03 Not applicable Do not change the default value 5 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installati...

Страница 22: ...rmation for diagnosing and correcting certain problems which may occur with the unit WARNING If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified person...

Страница 23: ......

Страница 24: ...4P404572 1 2015 04 Copyright 2015 Daikin...