English
4
When you want to change the setting time until the
•
mark is displayed, consult with your dealer.
(The default factory setting is 2500 hours.)
There are the following time, display pattern.
•
1250, 2500, 5000, 10000
Remove the air fi lter.
1.
Filter frame
Right- and left-hand-side
screws of product
Filter
Clean the fi lter or replace the fi lter with a new one.
2.
Push the “fi lter sign reset” button on the remote con-
3.
troller.
The display “
” vanishes.
WARNING
Do not let the indoor unit get wet as it may cause an electric
•
shock or fi re.
If the following phenomenon occurs, contact your dealer.
DANGER
Any abnormalities in the operation of the air condition-
•
er such as smoke or fi re could result in severe injury or
death.
Turn off the power and contact your dealer immediately for
instructions.
Phenomenon
The safety devices such as fuse, breaker, ground fault
•
interrupter, etc. often operate or operations of the operation
switch are unstable.
Take the following actions before contact.
Turn off the switch.
If the ON/OFF switch does not properly work;
•
Take the following actions before contact.
Turn off the main power switch.
Phenomenon
Water leaks out from the air conditioner.
•
Take the following actions before contact.
Stop the operation.
Phenomenon
The “OPERATION lamp”, “INSPECTION display” or “UNIT
•
No.” is winking and lit, and “MALFUNCTION CODE” is
displayed.
OPERATION lamp
INSPECTION
display
MALFUNCTION CODE
INDOOR UNIT No. in
which a malfunction occurs
UNIT No.
F
L
H
Take the following actions before contact.
Inform the dealer of the details being displayed on the
remote controller.
01_EN_3P250362-1.indd 4
01_EN_3P250362-1.indd 4
6/1/2009 1:31:59 PM
6/1/2009 1:31:59 PM