Wiring Diagrams
SiBE121021_C
484
Appendix
4MKS75F2V1B
5MKS90E2V3B
indoor
outdoor
FIELD WIRING
1
3.15A
B
A
YLW
S22
POWER SUPPLY
X4M
4
WHT
M1C
ROOM D
BLU
RED
BLU
WHT
7
3
3
~
YLW
1
W
1
ORG
BLU
7(N)
2
M1F
L1R
8
M
ORG
3
M
1
6
BRN
WHT
S93
5
AC2
L
YL
W
1
RED
FU2
D
V5
Z6C
2
2
12
7
1
WHT
SW5
1
WHT
Z3C
GRN
S70
BLU
N
SHEET METAL
6
WHT
1
1
1
RED
YL
W
1
S2
MRM10
30A
MRC/W
3
BLK
WHT
BLU
BRN
BLK
SW1
Y1E
SW2
BRN
3
RED
BRN
1
BLU
M
12
GRN
S52
5
BLK
U
BLK
GRN
GR
Y
1
S20
SW4
8
BLU
YLW
1
BLU
C
L
BLK
3.15A
FU3
3
Z2C
BRN
X1M
S23
1
S101
WHT
RED
1
M
PM1
YLW
AC1
PCB1
BLU
Z5C
6
BLU
YL
W
LED
M
RED
V
2
9
U
6
GR
Y
HR1
3
2
Z4C
Y3E
E1
BLK
1
X3M
Y4E
BLU
B
BLU
X11A
YL
W
YLW
RED
ORG
ROOM A
BLU
YL
W
BLK
WHT
RED
1
5
BLU
MRM20
BLU
Y2E
V2
D
BLU
ORG
V9
BLU
W
C
2
BLK
2
3
Z1C
BLU
S21
BLU
9
PCB2
ROOM C
E2
2
S15
RED
6
ORG
4
2
FU1
V100
1
1
BLK
5
3
3
A
V3
1
3
X5M
4
3
BLU
M
1
WHT
S102
6(P)
Q1L
ORG
WHT
2
WHT
BLK
N
BLU
1
1
BRN
V
3
A
X2M
WHT
BRN
1
S51
BLK
S90
SW3
S10
S80
GRN
RED
1
S92
RED
BLU
BLU
SA2
S40
HR2
BLK
t
°
t
°
t
°
t
°
t
°
t
°
t
°
t
°
t
°
t
°
t
°
+
+
+
(ROOM-B)
R9T
<GAS PIPE>
R8T
R5T
R2T
R6T
R3T
<LIQUID PIPE>
R10T
R4T
R1T
R11T
(ROOM-A) (ROOM-C)
R7T
(ROOM-D)
(ROOM-B)
(ROOM-A) (ROOM-C)
(ROOM-D)
TO INDOOR UNIT
ROOM B
(OUTDOOR) (DISCHARGE)
(CONDENSER)
Z1C~Z6C
X1M~X5M
Y1E~Y4E
V2, V3, V5, V9, V100
SA2
FU1, FU2, FU3
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2
: FERRITE CORE
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: VARISTOR
: SURGE ARRESTER
: FUSE
: CONNECTOR
MRM10, MRM20
MRC/W
R1T~R11T
S2~S102
LED1~LED4
LEDA
: MAGNETIC RELAY
: THERMISTOR
: CONNECTOR
: PILOT LAMP
L
N
SW1
SW2
SW3
SW4
SW5
: LIVE
: NEUTRAL
: FORCED OPERATION ON/OFF SW (SW1)
: SELECT SW (SW2)
: WIRING ERROR CHECK SW (SW3)
: PRIORITY ROOM SETTING SW (SW4)
: NIGHT QUIET MODE SETTING SW (SW5)
M1C
M1F
L1R
Q1L
PM1
PCB1, 2
SHEET METAL
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: POWER MODULE
: PRINTED CIRCUIT BOARD
: TERMINAL STRIP FIXED PLATE
3D055885
2TW57596-1
L: Live, N: Neutral, : Field wiring
: Terminal strip : Connector : Connection
Room C
Room A
Room A
Room B
Room C
Room D
Room E
Room A
Room B
Room C
Room D
Room E
Condenser
Discharge
Outdoor
Gas pipe
Liquid pipe
Room D
Room E
Indoor
Outdoor
Sheet
metal
BLK: Black
BRN: brown
WHT: White
RED: Red
BLU: Blue
GRY: Grey
ORG: Orange
YLW: Yellow
GRN: Green
To indoor unit
Room B
: Protective earth (screw) : Relay connector
: Terminal
Z1C~Z6C
X1M~X6M
Y1E~Y5E
V2,V3,V5
V9,V100
SA2
FU1,FU2,FU3
AC1,AC2
U,V,W,X11A
E1,E2E
HR1,HR2
MRM10,MRM20
MRC/W
: Ferrite core
: Terminal strip
: Electronic expansion valve coil
: Varistor
: Surge arrester
: Fuse
: Connector
: Magnetic relay
R1T~R3T
R4T~R8T
R9T~R13T
S2~S102
LED1~LED5
LEDA
SW1
SW2
SW3
SW4
SW5
M1C
M1F
L1R
: Thermistor
: Connector
: Light emitting diode
: Forced operation on/off switch (SW1)
: Operation mode select SW (SW2)
: Wiring error check SW (SW3)
: Priority room setting SW (SW4)
: Night quiet mode setting SW (SW5)
: Compressor motor
: Fan motor
: Reactor
Q1L
PM
PCB1,2
Sheet metal
F2U
Q1DI
: Overload protector
: Power module
: Printed circuit board
: Terminal strip fixed plate
: Field fuse
: Field earth leakage breaker
(300mA)