Piping Diagrams
SiBE121021_C
472
Appendix
1.2.2 Heat Pump
3MXS52E3V1B, 3AMX52E3V1B
3MXS68G2V1B
12.7CuT
7.9CuT
12.7CuT
12.7CuT
9.5CuT
6.4CuT
6.4CuT
6.4CuT
12.7CuT
12.7CuT
12.7CuT
(
(
)
)
OUTDOOR TEMPERATURE
THERMISTOR(DOA)
HEAT EXCHANGER
THERMISTOR(DE)
REVERSING
SOLENOID
VALVE
DISCHARGE PIPE
THERMISTOR (DO)
GAS LINE
STOP VALVE
LIQUID LINE
STOP VALVE
ELECTRONIC
EXPANSION VALVE
ELECTRONIC
EXPANSION VALVE
ELECTRONIC
EXPANSION VALVE
LIQUID PIPE
THERMISTOR(DLA)
LIQUID PIPE
THERMISTOR(DLA)
LIQUID PIPE
THERMISTOR(DLA)
FIELD
PIPING
LIQUID
SIDE
FIELD
PIPING
GAS
SIDE
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
ROOM C
(6.4 CuT)
ROOM A
(9.5 CuT)
ROOM B
(9.5 CuT)
ROOM C
(12.7 CuT)
HEADER
DC FAN MOTOR
PROPELLER FAN
M
MUFFLER
REFRIGERANT FLOW
COOLING
HEATING
COMPRESSOR
ACCUMULATOR
MUFFLER
MUFFLER
CAPILLARY TUBE
DISTRIBUTOR
HEADER
FILTER
EV
A
EV
B
EV
C
FILTER
FILTER
FILTER
GAS PIPE THERMISTOR(DGA)
GAS PIPE THERMISTOR(DGB)
GAS PIPE THERMISTOR(DGC)
HEADER
3D052055C
OUTDOOR UNIT
HEAT EXCHANGER
12.7CuT
12.7CuT
12.7CuT
12.7CuT
6.4CuT
12.7CuT
12.7CuT
12.7CuT
12.7CuT
9.5CuT
6.4CuT
7.9CuT
6.4CuT
OUTDOOR TEMPERATURE
THERMISTOR(DOA)
HEAT EXCHANGER
THERMISTOR(DE)
REVERSING
SOLENOID
VALVE
DISCHARGE PIPE
THERMISTOR(DO)
GAS LINE
STOP VALVE
LIQUID LINE
STOP VALVE
LIQUID PIPE
THERMISTOR(DLA)
LIQUID PIPE
THERMISTOR(DLB)
LIQUID PIPE
THERMISTOR(DLC)
FIELD
PIPING
LIQUID
FIELD
PIPING
GAS
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
ROOM C
(6.4 CuT)
ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
ROOM C
(12.7 CuT)
HEAT EXCHANGER
HEADER
DC FAN MOTOR
PROPELLER FAN
M
MUFFLER
REFRIGERANT FLOW
COOLING
HEATING
COMPRESSOR
ACCUMULATOR
ACCUMULATOR
CAPILLARY TUBE
DISTRIBUTOR
HEADER
FILTER
HEADER
GAS PIPE THERMISTOR(DGA)
GAS PIPE THERMISTOR(DGB)
GAS PIPE THERMISTOR(DGC)
FILTER
FILTER
FILTER
MOTOR OPERATED VALVE
MOTOR OPERATED VALVE
MOTOR OPERATED VALVE
EV
C
EV
B
EV
A
3D058888
OUTDOOR UNIT