Main Functions
SiENBE07-618_C
24
Function and Control
1.7
NIGHT SET Mode
Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in
the case of heating. This prevents excessive cooling in summer and excessive heating in winter
to ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Heating
Target temperature
Operation stops
at the set hours
Timer operation
Night Set Mode ON
When outside temperature is normal and room
temperature is at set temperature.
When outside temperature is high (27°C or higher).
+0.5°C
temperature shift
+0.5°C
temperature shift
Temperature setting remains the same
(R12237)
:
:
0.5°C
0.5°C
30 minutes
A
A
B
B
A
B
1 hour
2°C
(R10871)
Target temperature
1 hour later
Timer operation
Night Set Mode ON
SIENBE07-618_C_FRONT.pdf 36