• Outdoor Unit • RZQG-L(8)Y1
3
• Split - Sky Air • RZQG-L(8)Y1
16
3
Electrical data
3 - 1
Electrical Data
RZQG125-140L(8)Y1
/ŶĨƌĂƐƚƌƵĐƚƵƌĞ
Cooling
FCQHG71FVEB
x2
RZQG125L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,091 x2
0,5 x2
FCQHG140FVEB
RZQG125L8Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,244
1,4
FCQG35FVEB
x4
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,044 x4
0,3 x4
FCQG50FVEB
x3
RZQG125L8Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,039 x3
0,3 x3
FCQG71FVEB
x2
RZQG125L8Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,054 x2
0,4 x2
FCQG140FVEB
RZQG125L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,168
1,0
FFQ35C2VEB
x4
RZQG125L8Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,050 x4
0,4 x4
FFQ50C2VEB
x3
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,050 x3
0,4 x3
FBQ35D2VEB
x4
RZQG125L8Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,089 x4
0,6 x4
FBQ50D2VEB
x3
RZQG125L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,089 x3
0,6 x3
FBQ71D2VEB
x2
RZQG125L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,070 x2
0,5 x2
FBQ140D2VEB
RZQG125L8Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,187
1,5
FHQ35CAVEB
x4
RZQG125L8Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x4
0,6 x4
FHQ50CAVEB
x3
RZQG125L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x3
0,6 x3
FHQ71CAVEB
x2
RZQG125L8Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,091 x2
0,8 x2
FHQ140CAVEB
RZQG125L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,150
1,8
FUQ71CVEB
x2
RZQG125L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,046 x2
0,9 x2
FAQ71CVEB
x2
RZQG125L8Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,048 x2
0,4 x2
FVQ140CVEB
RZQG125L8Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,276
1,4
FDXS35F2VEB
x4
RZQG125L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,034 x4
0,3 x4
FDXS50F2VEB9
x3
RZQG125L8Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x3
0,5 x3
FCQHG71FVEB
x2
RZQG140L7Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,091 x2
0,5 x2
FCQHG140FVEB
RZQG140L7Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,244
1,4
FCQG35FVEB
x4
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,044 x4
0,3 x4
FCQG50FVEB
x3
RZQG140L7Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,039 x3
0,3 x3
FCQG71FVEB
x2
RZQG140L7Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,054 x2
0,4 x2
FCQG140FVEB
RZQG140L7Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,168
1,0
FFQ35C2VEB
x4
RZQG140L7Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,050 x4
0,4 x4
FFQ50C2VEB
x3
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,050 x3
0,4 x3
FBQ35D2VEB
x4
RZQG140L7Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,089 x4
0,6 x4
FBQ50D2VEB
x3
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,089 x3
0,6 x3
FBQ71D2VEB
x2
RZQG140L7Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,070 x2
0,5 x2
FBQ140D2VEB
RZQG140L7Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,187
1,5
FHQ35CAVEB
x4
RZQG140L7Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x4
0,6 x4
FHQ50CAVEB
x3
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x3
0,6 x3
FHQ71CAVEB
x2
RZQG140L7Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,091 x2
0,8 x2
FHQ140CAVEB
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,150
1,8
FUQ71CVEB
x2
RZQG140L7Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,046 x2
0,9 x2
FAQ71CVEB
x2
RZQG140L7Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,048 x2
0,4 x2
FVQ140CVEB
RZQG140L7Y1B
18,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,276
1,4
FDXS35F2VEB
x4
RZQG140L7Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,034 x4
0,3 x4
FDXS50F2VEB9
x3
RZQG140L7Y1B
18,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x3
0,5 x3
Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]
Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
3N~ 50Hz
380-415V
M
ini
m
u
m
: 342 V
M
a
x
im
u
m
456 V
3N~ 50Hz
380-415V
M
ini
m
u
m
: 342 V
M
a
x
im
u
m
456 V
MSC
RLA
kW
FLA
kW
FLA
Compressor
OFM
IFM
Indoor
Outdoor
Power supply
Voltage range
MCA
TOCA
MFA
3D098292
Содержание RZQG-L8Y1 Series
Страница 1: ...Air Conditioning Technical Data RZQG L 8 Y1 ...
Страница 2: ......
Страница 12: ... Outdoor Unit RZQG L 8 Y1 3 Split Sky Air RZQG L 8 Y1 10 3 Electrical data 3 1 Electrical Data ...
Страница 19: ...3 4 Split Sky Air RZQG L 8 Y1 17 Outdoor Unit RZQG L 8 Y1 4 Options 4 1 Options ...
Страница 27: ...3 6 Split Sky Air RZQG L 8 Y1 25 Outdoor Unit RZQG L 8 Y1 6 Capacity tables 6 3 Capacity Correction Factor ...
Страница 28: ... Outdoor Unit RZQG L 8 Y1 7 Split Sky Air RZQG L 8 Y1 26 7 Dimensional drawings 7 1 Dimensional Drawings ...
Страница 29: ...3 8 Split Sky Air RZQG L 8 Y1 27 Outdoor Unit RZQG L 8 Y1 8 Centre of gravity 8 1 Centre of Gravity ...
Страница 30: ... Outdoor Unit RZQG L 8 Y1 9 Split Sky Air RZQG L 8 Y1 28 9 Piping diagrams 9 1 Piping Diagrams ...
Страница 34: ... Outdoor Unit RZQG L 8 Y1 10 Split Sky Air RZQG L 8 Y1 32 10 Wiring diagrams 10 1 Wiring Diagrams Three Phase ...
Страница 35: ...3 11 Split Sky Air RZQG L 8 Y1 33 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 1 Sound Power Spectrum ...
Страница 36: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 34 11 Sound data 11 1 Sound Power Spectrum ...
Страница 37: ...3 11 Split Sky Air RZQG L 8 Y1 35 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 2 Sound Pressure Spectrum Cooling ...
Страница 38: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 36 11 Sound data 11 2 Sound Pressure Spectrum Cooling ...
Страница 39: ...3 11 Split Sky Air RZQG L 8 Y1 37 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 3 Sound Pressure Spectrum Heating ...
Страница 40: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 38 11 Sound data 11 3 Sound Pressure Spectrum Heating ...
Страница 43: ...3 12 Split Sky Air RZQG L 8 Y1 41 Outdoor Unit RZQG L 8 Y1 12 Installation 12 1 Installation Method ...
Страница 44: ... Outdoor Unit RZQG L 8 Y1 12 Split Sky Air RZQG L 8 Y1 42 12 Installation 12 1 Installation Method ...
Страница 45: ...3 13 Split Sky Air RZQG L 8 Y1 43 Outdoor Unit RZQG L 8 Y1 13 Operation range 13 1 Operation Range ...
Страница 46: ......