• Split - Sky Air • RZQG-L(8)Y1
11
• Outdoor Unit • RZQG-L(8)Y1
3
Electrical data
3 - 1
Electrical Data
RZQG71-100L8Y1
FCQG71EVEB
RZQG71L8Y1B
11,5
㸫
16
㸫
9,6
0,094
0,4
0,048
0,4
FCQHG71FVEB
RZQG71L8Y1B
11,6
㸫
16
㸫
9,6
0,094
0,4
0,091
0,5
FCQG35FVEB
×2
RZQG71L8Y1B
11,8
㸫
16
㸫
9,6
0,094
0,4
0.044×2
0.3×2
FCQG71FVEB
RZQG71L8Y1B
11,5
㸫
16
㸫
9,6
0,094
0,4
0,054
0,4
FFQ35C2VEB
×2
RZQG71L8Y1B
12,0
㸫
16
㸫
9,6
0,094
0,4
0.05×2
0.4×2
FDXS35F2VEB
×2
RZQG71L8Y1B
11,8
㸫
16
㸫
9,6
0,094
0,4
0.034×2
0.3×2
FBQ35C8VEB
×2
RZQG71L8Y1B
14,0
㸫
16
㸫
9,6
0,094
0,4
0.140×2
1.2×2
FBQ71C8VEB
RZQG71L8Y1B
12,4
㸫
16
㸫
9,6
0,094
0,4
0,350
1,1
FAQ71CVEB9
RZQG71L8Y1B
11,5
㸫
16
㸫
9,6
0,094
0,4
0,048
0,4
FVQ71CVEB
RZQG71L8Y1B
11,8
㸫
16
㸫
9,6
0,094
0,4
0,117
0,6
FHQ35CBVEB
x2
RZQG71L8Y1B
12,5
㸫
16
㸫
9,6
0,094
0,4
0,060x2
0,6 x 2
FHQ71CBVEB
RZQG71L8Y1B
12,0
㸫
16
㸫
9,6
0,094
0,4
0,091
0,8
FUQ71CVEB
RZQG71L8Y1B
12,1
㸫
16
㸫
9,6
0,094
0,4
0,046
0,9
FCQG100EVEB
RZQG100L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,106
1
FCQHG100FVEB
RZQG100L8Y1B
18,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,221
1,3
FCQG35FVEB
×3
RZQG100L8Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.044×3
0.3×3
FCQG50FVEB
×2
RZQG100L8Y1B
17,3
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.039×2
0.3×2
FCQG100FVEB
RZQG100L8Y1B
17,4
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,117
0,7
FFQ35C2VEB
×3
RZQG100L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×3
0.4×3
FFQ50C2VEB
×2
RZQG100L8Y1B
17,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.05×2
0.4×2
FDXS35F2VEB
×3
RZQG100L8Y1B
17,6
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.034×3
0.3×3
FDXS50F2VEB9
x2
RZQG100L8Y1B
17,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.06x2
0.5x2
FBQ35C8VEB
×3
RZQG100L8Y1B
21,0
㸫
25
㸫
14,2
0.094+0.094
0.4+0.4
0.140×3
1.2×3
FBQ50C8VEB
×2
RZQG100L8Y1B
19,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0.140×2
1.2×2
FBQ100C8VEB
RZQG100L8Y1B
18,5
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,350
1,6
FAQ100CVEB9
RZQG100L8Y1B
17,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,064
0,4
FVQ100CVEB
RZQG100L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,238
1,2
FHQ35CBVEB
x3
RZQG100L8Y1B
18,8
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x 3
0,6 x 3
FHQ50CBVEB
x2
RZQG100L8Y1B
18,0
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,060 x 2
0,6 x 2
FHQ100CBVEB
RZQG100L8Y1B
18,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,150
1,3
FUQ100CVEB
RZQG100L8Y1B
18,1
㸫
20
㸫
14,2
0.094+0.094
0.4+0.4
0,106
1,3
Symbols
MCA: Minimum Circuit Ampere [A]
TOCA: Total overcurrent amps [A]
MFA: Maximum Fuse Ampere [A]
MSC: Maximum current of the starting compressor [A]
RLA: Rated load amps [A]
OFM: Outdoor fan motor
IFM: Indoor fan motor
FLA: Full Load Ampere [A]
KW: Fan motor rated output [kW]
Notes
1. The RLA is based on the following conditions.
Cooling
Indoor temperature 27.0°C DB / 19.0°C WB
Outdoor temperature 35.0°C DB
Heating
Indoor temperature 20.0°C DB
Outdoor temperature 7.0°C DB / 6.0°C WB
2. TOCA is the total value of each overcurrent set.
3. Voltage range
The units are suitable for use with electrical systems in which the voltage supplied to the unit terminals is not below or above the listed range limits.
4. The maximum allowable voltage that is unbalanced between phases is 2%.
5. MCA is the maximum input current.
The capacity of the MFA must be greater than that of the MCA.
Select the MFA according to the table.
6. Select the wire size according to the MCA.
7. MFA is used to select the circuit breaker and the ground fault circuit interruptor.
Earth leakage circuit breaker
FLA
Compressor
OFM
IFM
Indoor
Outdoor
Power supply
Voltage
range
MCA
TOCA
MFA
MSC
RLA
kW
FLA
kW
3N~ 50Hz
380-415V
Min
imu
m:
34
2 V
Max
imum 456 V
3N~ 50Hz
380-415V
Min
imu
m:
34
2 V
Max
imum 456 V
3D077810C
Содержание RZQG-L8Y1 Series
Страница 1: ...Air Conditioning Technical Data RZQG L 8 Y1 ...
Страница 2: ......
Страница 12: ... Outdoor Unit RZQG L 8 Y1 3 Split Sky Air RZQG L 8 Y1 10 3 Electrical data 3 1 Electrical Data ...
Страница 19: ...3 4 Split Sky Air RZQG L 8 Y1 17 Outdoor Unit RZQG L 8 Y1 4 Options 4 1 Options ...
Страница 27: ...3 6 Split Sky Air RZQG L 8 Y1 25 Outdoor Unit RZQG L 8 Y1 6 Capacity tables 6 3 Capacity Correction Factor ...
Страница 28: ... Outdoor Unit RZQG L 8 Y1 7 Split Sky Air RZQG L 8 Y1 26 7 Dimensional drawings 7 1 Dimensional Drawings ...
Страница 29: ...3 8 Split Sky Air RZQG L 8 Y1 27 Outdoor Unit RZQG L 8 Y1 8 Centre of gravity 8 1 Centre of Gravity ...
Страница 30: ... Outdoor Unit RZQG L 8 Y1 9 Split Sky Air RZQG L 8 Y1 28 9 Piping diagrams 9 1 Piping Diagrams ...
Страница 34: ... Outdoor Unit RZQG L 8 Y1 10 Split Sky Air RZQG L 8 Y1 32 10 Wiring diagrams 10 1 Wiring Diagrams Three Phase ...
Страница 35: ...3 11 Split Sky Air RZQG L 8 Y1 33 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 1 Sound Power Spectrum ...
Страница 36: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 34 11 Sound data 11 1 Sound Power Spectrum ...
Страница 37: ...3 11 Split Sky Air RZQG L 8 Y1 35 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 2 Sound Pressure Spectrum Cooling ...
Страница 38: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 36 11 Sound data 11 2 Sound Pressure Spectrum Cooling ...
Страница 39: ...3 11 Split Sky Air RZQG L 8 Y1 37 Outdoor Unit RZQG L 8 Y1 11 Sound data 11 3 Sound Pressure Spectrum Heating ...
Страница 40: ... Outdoor Unit RZQG L 8 Y1 11 Split Sky Air RZQG L 8 Y1 38 11 Sound data 11 3 Sound Pressure Spectrum Heating ...
Страница 43: ...3 12 Split Sky Air RZQG L 8 Y1 41 Outdoor Unit RZQG L 8 Y1 12 Installation 12 1 Installation Method ...
Страница 44: ... Outdoor Unit RZQG L 8 Y1 12 Split Sky Air RZQG L 8 Y1 42 12 Installation 12 1 Installation Method ...
Страница 45: ...3 13 Split Sky Air RZQG L 8 Y1 43 Outdoor Unit RZQG L 8 Y1 13 Operation range 13 1 Operation Range ...
Страница 46: ......