*1: Refrigerant charge at factory shipment
3. WHAT TO DO BEFORE OPERATION
This operation manual is for the following system
with standard control. Before initiating operation,
contact your Daikin dealer for the operation that cor-
responds to your system type and mark.
If your installation has a customized control system,
ask your Daikin dealer for the operation that corre-
sponds to your system.
Outside units
(Refer to figure 1)
• Names and functions of parts (Refer to figure 1)
1. Outside unit
2. Indoor unit
3. Remote controller
4. Inlet air
5. Outlet air
6. BS unit
7. Cool/Heat selector
8. Refrigerant piping
(figure 1 shows system with Cool/Heat selector)
4. REMOTE CONTROLLER AND
COOL/HEAT SELECTOR : NAME
AND FUNCTION OF EACH
SWITCH AND DISPLAY
(Refer to figure 2 and 3)
1. On/off button
Press the button and the system will start. Press
the button again and the system will stop.
2. Operation lamp (red)
The lamp lights up during operation.
Model name
REYQ144PYDN REYQ168PYDN REYQ192PYDN
Power supply
Phase
—
3~
3~
3~
Frequency
(Hz)
60
60
60
Voltage
(V)
460
460
460
Nominal cooling capacity
(MBh)
144
168
192
Nominal heating capacity
(MBh)
162
189
216
(66-1/8×36-5/
8×30-1/8)+
(66-1/8×36-5/
8×30-1/8)+
(66-1/8×36-5/
8×30-1/8)+
Dimensions H×W×D
(inch)
(66-1/8×36-5/
8×30-1/8)
(66-1/8×36-5/
8×30-1/8)
(66-1/8×36-5/
8×30-1/8)
Mass
(Ib)
463+463
463+573
463+573
Refrigerant
type
—
R410A
R410A
R410A
charge (*1)
(Ib)
18.1+18.1
18.1+19.8
19.8+19.8
Design pressure
High side
(psig)
478
478
478
Low side
(psig)
320
320
320
Model name
REYQ216PYDN REYQ240PYDN
Power supply
Phase
—
3~
3~
Frequency
(Hz)
60
60
Voltage
(V)
460
460
Nominal cooling capacity
(MBh)
216
240
Nominal heating capacity
(MBh)
243
270
(66-1/8×36-5/
8×30-1/8)+
(66-1/8×36-5/
8×30-1/8)+
Dimensions H×W×D
(inch)
(66-1/8×36-5/
8×30-1/8)
(66-1/8×36-5/
8×30-1/8)
Mass
(Ib)
573+573
573+573
Refrigerant
type
—
R410A
R410A
charge (*1)
(Ib)
18.1+20.1
20.1+20.1
Design pressure
High side
(psig)
478
478
Low side
(psig)
320
320
Model name
REYQ72PTJU
REYQ96PTJU
REYQ120PTJU
Power supply
Phase
—
3~
3~
3~
Frequency
(Hz)
60
60
60
Voltage
(V)
208-230
208-230
208-230
Nominal cooling capacity
(MBh)
72
96
120
Nominal heating capacity
(MBh)
81
108
135
Dimensions H×W×D
(inch)
66-1/8×
51-3/16×
30-1/8
66-1/8×
51-3/16×
30-1/8
66-1/8×
51-3/16×
30-1/8
Mass
(Ib)
730
730
730
Refrigerant
type
—
R410A
R410A
R410A
charge (*1)
(Ib)
22.7
23.4
23.8
Design pressure
High side
(psig)
478
478
478
Low side
(psig)
320
320
320
Model name
REYQ144PTJU REYQ168PTJU REYQ192PTJU
Power supply
Phase
—
3~
3~
3~
Frequency
(Hz)
60
60
60
Voltage
(V)
208-230
208-230
208-230
Nominal cooling capacity
(MBh)
144
168
192
Nominal heating capacity
(MBh)
162
189
216
Dimensions H×W×D
(inch)
66-1/8×
51-3/16×
30-1/8
(66-1/8×36-5/8×
30-1/8)+
(66-1/8×36-5/8×
30-1/8)
(66-1/8×36-5/8×
30-1/8)+
(66-1/8×36-5/8×
30-1/8)
Mass
(Ib)
747
450+560
450+560
Refrigerant
type
—
R410A
R410A
R410A
charge (*1)
(Ib)
24.5
18.1+19.8
18.1+20.1
Design pressure
High side
(psig)
478
478
478
Low side
(psig)
320
320
320
Model name
REYQ216PTJU REYQ240PTJU
Power supply
Phase
—
3~
3~
Frequency
(Hz)
60
60
Voltage
(V)
208-230
208-230
Nominal cooling capacity
(MBh)
216
240
Nominal heating capacity
(MBh)
243
270
Dimensions H×W×D
(inch)
(66-1/8×36-5/8×
30-1/8)+
(66-1/8×36-5/8×
30-1/8)
(66-1/8×36-5/8×
30-1/8)+
(66-1/8×36-5/8×
30-1/8)
Mass
(Ib)
560+560
560+560
Refrigerant
type
—
R410A
R410A
charge (*1)
(Ib)
19.8+20.1
20.1+20.1
Design pressure
High side
(psig)
478
478
Low side
(psig)
320
320
COOL/HEAT selector
Operation modes
Inverter series
heat pumps
RXYQ
series
❏
yes
❏
no
Heat recovery series
heat pumps
REYQ
series
❏
yes
❏
no
01_EN_3P215731-1D.fm Page 5 Tuesday, February 5, 2008 6:35 PM