![Daikin RXS100HVMA Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/daikin/rxs100hvma/rxs100hvma_service-manual_2459941013.webp)
Si00-978
Removal of Outer Panels (Pattern 2)
Removal Procedure
11
2. Removal of Outer Panels (Pattern 2)
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Appearance features.
The design of discharge
grille is different depending
on the model.
2. Remove the suction grille.
The hooks are secured in
the clearances of the
outdoor heat exchanger fins.
1
Unfasten the 3 hooks at
the upper first, and then
3 hooks at the middle.
2
Unfasten the 3 hooks at
the bottom and remove
the suction grille.
3. Remove the top panel.
1
Remove the 9 screws
and remove the top
panel.
(R16618)
(R16619)
Suction grille
(R9587)
(R16620)
Top panel