Outdoor Unit Installation Drawings
1.
Precautions for humidifying hose installation work.
• Moisture on the outdoor unit is brought to the indoor unit together with air around the outdoor unit during humidifying
operation. Install the outdoor unit in a clean and calm location.
• When embedding humidifying hose:
1) Cannot be installed to the existing embedded piping. Embedding work is separately necessary.
• The length of the humidifying hose is marked on the hose packing material.
1) Use an extension hose (sold separately) when extending the humidifying hose.
2) The length of the humidifying hose needs to be set to ensure humidifying capacity. Cut off any excess hose.
Use the remote controller to set the hose length.
• When it is difficult to install without cutting the humidifying hose, cut the hose and join it with included joint or elbow
after the installation. When doing this, bind the hose using included binding band so that there is no air leakage.
(Refer to
Connecting the Humidifying Hose
on page 8.)
• When laying the humidifying hose inside the wall, block the ends of the humidifying hose with tape or the like to
prevent water or anything else from entering it until it is connected to the indoor unit and outdoor unit ducts.
• Do not bend the humidifying hose more than 90°.
C
C
C
C
C
D
E
F
C
C
C
*
No refrigerant needs to be added if the piping does not
exceed the maximum length.
**
The suggested shortest pipe length is 1.5m, in order to avoid
noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how
the unit is installed and the environment in which it is used.)
Wrap the insulation pipe with
the finishing tape from bottom
to top.
In sites with poor drainage, use
block bases for outdoor unit.
Adjust foot height until the unit
is leveled. Otherwise, water
leakage or pooling of water may
occur.
574
(Foot bolt-hole centres)
(From unit’
s side)
(Foot bolt-hole
centres)
311
250mm from w
all
Unit: mm
How to remove the stop valve cover.
Remove the screw on the
stop valve cover.
Slide the lid downward
to remove it.
How to attach the stop valve cover.
Insert the upper part of the
stop valve cover into the
outdoor unit to install.
Tighten the screws.
Stop valve cover
O.D. 9.5mm
Gas pipe
Liquid pipe
O.D. 6.4mm
8m
10m
Max. allowable length
Max. allowable height
105.5
Humidifying hose
C
Allow space for piping
and electrical servicing.
*
**
CAUTION
** Set the piping length
from 1.5m to 10m.
Where there is a danger
of the unit falling, use
foot bolts, or wires.
1.5m
Min. allowable length