Si341211
Procedure to Remove PCB and Electrical Component Box
Removal Procedure
9
Step
Procedure
Points
10
Cut off the clamp
materials, for fixing the
compressor lead wires
(2 places) and the lead
wires A3P to X11 (red,
blue, and green colors)
(1 place).
Clamps (2 places) for the
compressor lead wires
Clamps for the lead wires A3P to
X11
11
Fold the hooks (2
places) and slide the
resin casing to the right
to remove the casing
from the electrical
component assembly.
Hooks