Specifications
Standard Accessories : Drain plug; Quantity : 1;
Standard Accessories : Installation manual; Quantity : 1;
Standard Accessories : Refrigerant charge label; Quantity : 1;
Standard Accessories : Multilingual fluorinated greenhouse gases labels; Quantity : 1;
Notes
Contains fluorinated greenhouse gases
See separate drawing for operation range
See separate drawing for electrical data
Fan
Type
Propeller fan
Propeller
Air flow rate
Cooling Nom.
m³/min
36.0
50.4
cfm
1,271
1,780
Heating Nom.
m³/min
28.3
40.4
cfm
999
1,427
Fan motor
Model
ARW34W8P50DA
ARW7406DA
Output
W
50
68
Speed
Cooling High
rpm
920
780
Nom.
rpm
920
780
Low
rpm
800
690
620
Super
low
rpm
-
Heating High
rpm
860
730
Nom.
rpm
800
730
Low
rpm
400
530
Super
low
rpm
-
Sound power level
Cooling
dBA
59
61
62
63
Heating
dBA
59
61
62
63
Sound pressure level
Cooling
Nom.
dBA
46
49
48
Heating
Nom.
dBA
47
49
48
49
Refrigerant
Type
R-32
Charge
kg
0.76
1.30
1.40
1.45
TCO
2
eq
0.52
0.88
0.95
0.98
GWP
675.0
Piping connections
Liquid
OD
mm
6,35
6,4
Gas
OD
mm
9.50
12.7
Drain
OD
mm
18
ID
mm
-
Piping length
OU - IU Max.
m
20.0
30
System Chargel
ess
m
10.0
-
Additional refrigerant charge
kg/m
0.02 (for piping length exceeding 10m)
Level difference
IU - OU Max.
m
20.0
Heat insulation
Both liquid and gas pipes
-
2-9 Electrical Specifications
RXM20M9
RXM25M9
RXM35M9
RXM42M9
RXM50M9
RXM60M9
Power supply
Phase
1~
Frequency
Hz
50
Voltage
V
220-240
Current - 50Hz
Maximum fuse amps (MFA)
A
-
Current - 60Hz
Maximum fuse amps (MFA)
A
-
Wiring connections
For power supply
Quantity
3
Remark
Earth wire included
For connection with indoor
Quantity
4
Remark
Earth wire included
2-8 Technical Specifications
RXM20M9
RXM25M9
RXM35M9
RXM42M9
RXM50M9
RXM60M9