background image

Si01-780

Removal of Partition Plate

Removal Procedure

7

4. Removal of Partition Plate

Procedure

Warning     Be sure to wait 10 minutes or more after turning off all power supplies 

before disassembling work.

Step

Procedure

Points

1

Remove the 2 screws 
of the partition plate.

2

Unfasten the hooks of 
the bottom frame and 
remove the partition 
plate.

Hooks of bottom frame

Partition plate

(R12559)

Содержание RW25JV1

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 5 kW Class Outdoor Unit Non Inverter Pair Type Si01 780 ...

Страница 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only RW25JV1 RW35JAV1 ...

Страница 3: ...ontents 1 Removal of Outer Panel 2 2 Removal of Electrical Component ASSY 3 3 Removal of Outdoor Fan Fan Motor 6 4 Removal of Partition Plate 7 5 Removal of Compressor 8 Note The illustrations may be slightly different depending on the model ...

Страница 4: ... Step Procedure Points 1 Remove the 3 screws and remove the top panel 2 Remove the 2 screws of the discharge grille 3 Unfasten the each 2 hooks at part A part B part C Slide the discharge grille to the direction shown by the arrow and remove it 4 Remove the 6 screws and remove the front panel Discharge grille Top panel R12548 B C A R12549 Front panel Lower right hand at the rear side R12550 ...

Страница 5: ... Points In case of service work without top panel 1 Remove the screw and remove the service cover 2 Remove the 2 screws of the electrical component ASSY 3 Lift up and remove the electrical component ASSY 4 Cut the clamp and disconnect the 3 connectors for the fan motor lead wire R12553 R12730 Service cover Electrical component ASSY R12551 Fan motor lead wire Red Clamp Fan motor lead wire White Fan...

Страница 6: ...over 2 Remove the 2 screws of the electrical component ASSY 1 Remove the electrical component ASSY 1 Unfasten the hook as shown with arrow 1 in the illustration 2 Pull out the electrical component ASSY as shown with arrow 2 in the illustration Step Procedure Points Service cover R12729 R12730 Hook 1 2 R12731 R12556 Electrical component ASSY R12554 ...

Страница 7: ...ASSY Removal Procedure 5 2 Disconnect the fan motor lead wires 1 Cut the clamp and disconnect the 3 connectors for the fan motor lead wire Step Procedure Points Fan motor lead wire Red Fan motor lead wire White Fan motor lead wire Black R12552 ...

Страница 8: ...en reassembling align the mark of the outdoor fan with the D cut section of the motor shaft 2 Remove the 2 screws and remove the fan motor fixing frame 3 Remove the 2 screws and remove the fan motor 4 Cut the 3 clamps and release the fan motor lead wire 5 Cut the clamp and disconnect the connectors for the fan motor lead wire R12557 Fan motor fixing frame Outdoor fan 10 mm R12236 Fan motor lead wi...

Страница 9: ...ure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the 2 screws of the partition plate 2 Unfasten the hooks of the bottom frame and remove the partition plate Hooks of bottom frame Partition plate R12559 ...

Страница 10: ...p Procedure Points Before working make sure that the refrigerant is empty in the circuit Be sure to apply nitrogen replacement when heating up the brazed part 1 Remove the sound blankets 2 Disconnect the compressor wire harnesses Acoustic insulation material of compressor RR187 Terminal cover Compressor lead wires Yellow Wire harness Blue Blue Red Blue Red Blue Soundproof material RR188 Yellow ...

Страница 11: ...Si01 780 Removal of Compressor Removal Procedure 9 3 Heat up the 2 brazed parts and disconnect them 4 Remove the 3 nuts and remove the compressor Step Procedure Points R12561 R12562 ...

Страница 12: ...Revision History Month Year Version Revised contents 07 2013 Si01 780 First edition ...

Страница 13: ...sories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion z Read the User s Manual carefully before using this product The User s Manual provides important safety instruc...

Отзывы: