2. SPECIFICATIONS

[Single unit] 

*1: Initial refrigerant charge

[Combination unit]

RQYQ18~48PY1B is the combination unit that is com-
posed of the single units.
About the specifications see 

Single unit

 according 

to the independent unit.

3. WHAT TO DO BEFORE OPERATION

This operation manual is for the following system 
with standard control. Before initiating operation, 
contact your Daikin dealer for the operation that cor-
responds to your system type and mark.

If your installation has a customized control system, 
ask your Daikin dealer for the operation that corre-
sponds to your system.

Outdoor units 

(Refer to figure 1)

Names and functions of parts (Refer to figure 1)

1. Outdoor unit
2. Indoor unit
3. Remote controller
4. Inlet air
5. Outlet air
6. Cool/Heat selector

(figure 1 shows system with Cool/Heat selector)

4. REMOTE CONTROLLER AND 

COOL/HEAT SELECTOR: NAME 
AND FUNCTION OF EACH 
SWITCH AND DISPLAY 
(Refer to figure 2 and 3)

1. On/off button

Press the button and the system will start. Press 
the button again and the system will stop.

2. Operation lamp (red)

The lamp lights up during operation.

3. Display 

 (changeover under control)

It is impossible to changeover heat/cool with the 
remote controller which display this icon.

4. Display 

 (air flow flap)

Refer to the chapter “Operation procedure - 
Adjusting the air flow direction”.

5. Display 

 (ventilation/air cleaning)

This display shows that the ventilation unit are in 
operation. (these are optional accessories)

6. Display 

 (set temperature)

This display shows the temperature you have set.

7. Display 

 

 

 

 

 (operation 

mode)

This display shows the current operation mode.

8. Display 

 (programmed time)

This display shows the programmed time of the 
system start or stop.

9. Display 

 (inspection/test operation)

When the inspection/test operation button is 
pressed, the display shows the mode in which 
the system actually is.

10. Display 

 (under centralized control)

When this display shows, the system is under 
centralized control. (This is not a standard spec-
ification.)

11. Display 

 (fan speed)

This display shows the fan speed you have 
selected.

12. Display 

 (time to clean air filter)

Refer to the operation manual of indoor unit.

13. Display 

 (defrost/hot start)

Refer to the chapter “Operation procedure - 
Explanation of heating operation.”

14. Timer mode start/stop button

Refer to the chapter “Operation procedure - 
Programming start and stop of the system with 
timer.”

15. Timer on/off button

Refer to the chapter “Operation procedure - 
Programming start and stop of the system with timer.”

Model

RQYQ8PY1B

RQYQ10PY1B RQYQ12PY1B

Power supply

Phase

-

3N

3N

3N

Frequency

(Hz)

50.0 50.0 50.0 

Voltage

(V)

380-415

380-415

380-415

Nominal cooling capacity

(kW)

22.4 28.0 33.5 

Nominal heating capacity

(kW)

25.0 31.5 37.5 

Dimensions H×W×D

(mm) 1680×930×765 1680×930×765 1680×930×765

Mass

(kg)

230 284

284

Refrigerant type

-

R410A

R410A

R410A

Refrigerant charge

 (*1)

(kg)

10.8 11.7 11.7 

Design pressure

High pressure side

(bar)

40

40

40

(MPa)

4.0

4.0

4.0

Low pressure side

(bar)

33

33

33

(MPa)

3.3

3.3

3.3

Model

RQYQ14PY1B RQYQ16PY1B

Power supply

Phase

-

3N

3N

Frequency

(Hz)

50.0 50.0 

Voltage

(V)

380-415

380-415

Nominal cooling capacity

(kW)

40.0 45.0 

Nominal heating capacity

(kW)

45.0 50.0 

Dimensions H×W×D

(mm) 1680×1240×765 1680×1240×765

Mass

(kg)

381

381

Refrigerant type

-

R410A

R410A

Refrigerant charge

 (*1)

(kg)

11.7

11.7

Design pressure

High pressure side

(bar)

40

40

(MPa)

4.0

4.0

Low pressure side

(bar)

33

33

(MPa)

3.3

3.3

Cool/Heat selector

Operation modes

Inverter series

“VRV

III

-Q” series

 yes   

 no

C

TEST

01_EN_3P226891-12Q.fm  Page 4  Saturday, November 27, 2010  2:08 PM

Содержание RQYQ8PY1B

Страница 1: ...RQYQ18PY1B RQYQ20PY1B RQYQ22PY1B RQYQ24PY1B RQYQ26PY1B RQYQ28PY1B RQYQ30PY1B RQYQ32PY1B RQYQ34PY1B RQYQ36PY1B RQYQ38PY1B RQYQ40PY1B RQYQ42PY1B RQYQ44PY1B RQYQ46PY1B RQYQ48PY1B English Deutsch Fran ais...

Страница 2: ...00_CV_3P226891 12Q fm Page 2 Saturday November 27 2010 2 07 PM...

Страница 3: ...entoenunlugarseguro Unavezquerecibalatarjetadegarant adelconcesionario gu rdelaen unlugarseguro Grazieperavere acquistato questo condizionatore d ariaDaikin Prima di utilizzarequest ultimo leggereatte...

Страница 4: ...2 1 4 3 5 6 7 1 7 3 7 2 00_CV_3P226891 12Q fm Page 4 Saturday November 27 2010 2 07 PM...

Страница 5: ...8 9 10 11 12 13 14 00_CV_3P226891 12Q fm Page 5 Saturday November 27 2010 2 07 PM...

Страница 6: ...00_CV_3P226891 12Q fm Page 6 Saturday November 27 2010 2 07 PM...

Страница 7: ...e circum stances After reading keep this manual in a conve nient place so that you can refer to it whenever necessary If the equipment is transferred to a new user be sure also to hand over the man ua...

Страница 8: ...or in places with flammable gas corrosive gas or metal dust Using the product in such places may cause fire or product failures Do not use flammable materials e g hairspray or insecticide near the pr...

Страница 9: ...y do not play with the unit or its remote con troller Accidental operation by a child may result in impairment of bodily functions and harm health Do not let children play on or around the out door un...

Страница 10: ...ime of the system start or stop 9 Display inspection test operation When the inspection test operation button is pressed the display shows the mode in which the system actually is 10 Display under cen...

Страница 11: ...nd humidity ranges for safe and effective operation NOTE To avoid condensation and water dripping out the unit If the temperature or the humidity is beyond these conditions safety devices may work and...

Страница 12: ...an in cooling operation We recommend starting the operation which was used before using timer operation The following operation is performed in order to prevent the heating capacity from dropping or c...

Страница 13: ...wings as shown right and the air flow direction continuously varies Automatic swing setting Press the air flow direction adjust but ton to select the air direction of your choice The air flow flap dis...

Страница 14: ...changeover under control of all slave remote controllers connected to the same outdoor unit flashes Press the operation mode selector button of the controller that you wish to designate as the master...

Страница 15: ...aracters in the remote controller display appear To protect the unit turn the power on at least 6 hours before operating it This makes operation smoother 8 2 AT THE END OF THE SEASON On a clear day us...

Страница 16: ...tion requires a qualified service person Immediately after the cooling operation stops and if the room temperature and humidity are low This is because warm refrigerant gas flows back into the indoor...

Страница 17: ...ns occur take the measures shown below and contact your Daikin dealer WARNING Stop operation and shut off the power if any thing unusual occurs burning smells etc Leaving the unit running under such c...

Страница 18: ...ove oil gas cooker etc it will cause toxic gas to be generated When a refrigerant leakage failure has been repaired confirm a service person that the leak age point has been corrected surely before re...

Страница 19: ...ong as possible Use for appropriate maintenance design budgeting maintenance and inspection fees etc Contact your dealer for details Note Breakage due to taking apart or cleaning inside by anyone othe...

Страница 20: ...3P226891 12Q EM10A039 1012 HT 00_CV_3P226891 12Q fm Page 7 Saturday November 27 2010 2 07 PM...

Отзывы: