R(Y)P71~W1
Split System air conditioners
4PW14486-1B
Installation manual
11
Precautions regarding test-runs
■
If the remote control shows E0, E3 or E4 as an error code, there
is a possibility that either the shut-off valve is closed, or the
outlet vent is closed.
■
For reverse or missing phase, U1 will be displayed on the
remote control for the indoor unit, and operation will be
impossible. If this happens, turn off the power, re-check the
wiring and switch the position of two of the three electrical wires.
(If operation is not possible, do not under any circumstances
force the electromagnetic contactor on.)
■
If the error code E6 is displayed on the remote contol, check for
voltage imbalance.
■
If the error code UF is displayed on the remote contol, check the
inter-unit branch wiring connection.
Diagnosis
■
On the remote control LCD
If the machine stops due to some malfunction, you can diagnose
the problem using the error code displayed on the remote
control.
-
The malfunction code should be looked up in the installation
manual for the indoor unit.
-
Depending on the indoor unit or outdoor unit type, error
codes may not be displayed.
D
ISPOSAL
REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, oil and any other
parts should be done in accordance with the relevant local and
national regulations.
N
OTES
Error code
Description
E0
Safety device activated (indoor/outdoor fan malfunction,
compressor malfunction, electric motor malfunction)
F6
Heat exchange temperature malfunction
J2
Electric current sensor malfunction
Содержание RP71L7V1
Страница 3: ...7 7 8 8 NOTES...