Si011415E
Outdoor Fan / Fan Motor
Removal Procedure
5
5
Remove the screw and
remove the fan motor
fixing frame.
Be careful so as not to
damage the top part of the
outdoor heat exchanger fins.
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
When reassembling, fit the 2
lower hooks into the bottom
frame.
6
Unfasten the 2 hooks
on the fan motor fixing
frame and release the
fan motor lead wire.
7
Remove the 4 screws
and remove the fan
motor.
Screw size: M4 × 12
Step
Procedure
Points
Fan motor fixing frame
(R21449)
(R21450)
Lead wire
Outdoor fan
(R3249)
(R21452)
Hook
Fan motor
lead wire
(R21451)
Fan motor
(R21453)
Содержание RNE50LV1