Coils / Thermistors
Si001271EE
12
Removal Procedure
5. Coils / Thermistors
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Pull out the electronic
expansion valve coil.
2
Remove the screw and
remove the four way
valve coil.
The cooling only models
have no four way valve coil.
3
Pull out the outdoor
heat exchanger
thermistor.
Be careful not to lose the clip
for the thermistor.
Electronic
expansion
valve coil
(R11159)
Four way
valve coil
(R18110)
Outdoor heat exchanger thermistor
(R11160)
Clip
(R3264)