Si001409EB
PCB
Removal Procedure
11
4. PCB
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw, and
then the electrical box
cover.
Some models have sealing
material.
2
3
Disconnect the 3
connectors from the
terminal board.
Remove the screw and
release the earth/
ground wire (upper).
4
Cut the clamp.
Electrical
box cover
Sealing
material
(R23682)
Connector
(R23794)
Earth/ground wire (upper)
screw
(R20237)
HN1 (white)
HL1 (black)
S (red)
Clamp
(R20618)