background image

Service Manual

Removal Procedure

Outdoor Unit

z

Cooling Only

z

Heat Pump

RKD50BVM

RKS50B2VMB

ARXS50CVMB

RXS50B2VMB

RKD60BVM

RKS60B2VMB

ARXS50C2VMB RXS60B2VMB

RKD71BVM

RKS71B2VMB

RXS71B2VMB

RKS71B3VMB

RXD50BV4

RXS71B3VMB

RKD50BVMA

RXD80CV4

RKD60BVMA

RKS50BVMA

RXS50BVMA

RKD71BVMA

RKS60BVMA

RXD50BVMA

RXS60BVMA

RKD60BVMA9

RKS71BVMA

RXD60BVMA

RXS71BVMA

RXD71BVMA

RKD50BVMT

RKS50BVMB

RXS50BVMB

RKD60BVMT

RKS60BVMB

RXD50BVMT

RXS60BVMB

RKD71BVMT

RKS71BVMB

RXD60BVMT

RXS71BVMB

RKS50BVMB9

RXD71BVMT

RKD18BVMS

RKS60BVMB9

RYS50B2VMB

RKD24BVMS

RKS71BVMB9

RYS60B2VMB

RKD28BVMS

RYS50BVMB

RKS50BVMG

RYS60BVMB

RS50B2VMB

RS60B2VMB

RS50BVMB

RS60BVMB

Содержание RKD50BVM

Страница 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 5 0 6 0 7 1 8 0 kW Class 18000 24000 28000 Btu h Class Outdoor Unit Inverter Hybrid Pair Type Si00 876...

Страница 2: ...MB RKD50BVMA RXD80CV4 RKD60BVMA RKS50BVMA RXS50BVMA RKD71BVMA RKS60BVMA RXD50BVMA RXS60BVMA RKD60BVMA9 RKS71BVMA RXD60BVMA RXS71BVMA RXD71BVMA RKD50BVMT RKS50BVMB RXS50BVMB RKD60BVMT RKS60BVMB RXD50BV...

Страница 3: ...l of PCBs Electrical Box 10 4 Removal of Reactor 17 5 Removal of Sound Blankets 19 6 Removal of the Four Way Valve 21 7 Removal of Electronic Expansion Valve 22 8 Removal of Compressor 23 Note The ill...

Страница 4: ...ll power supplies before disassembling work Step Procedure Points 1 Remove the panels Take care not to cut your finger by the fins of the outdoor heat exchanger 1 Remove the 4 screws and lift the top...

Страница 5: ...scharge grille has 4 hooks 3 Remove the 6 screws of the front panel 4 Push the front panel and lift the shield plate to unfasten the hooks Step Procedure Points R2679 Front panel R2680 Shield plate R1...

Страница 6: ...hooks and then the right side hook Remove the front panel Lift the front panel while pushing the left side panel inward Lift the front panel and unfasten the right side hook When reassembling the fron...

Страница 7: ...edure 5 2 Remove the stop valve cover 1 Remove the screw of the stop valve cover 2 Pull the stop valve cover downward to unfasten the hooks and remove it The stop valve cover has 6 hooks Step Procedur...

Страница 8: ...Procedure Points 1 Remove the electrical box cover Preparation Remove the top panel and the front panel according to the Removal of Outer Panels This procedure is not necessary to remove the outdoor f...

Страница 9: ...Fan Motor Removal Procedure 7 2 Remove the fan motor 1 Disconnect the connector for the fan motor S70 2 The illustration shows arrangement of the fan motor lead wire Step Procedure Points R16431 S70...

Страница 10: ...ut section of the motor shaft 4 Remove the 2 lower screws from the fan motor first Be sure to remove the lower screws first If the top screws are removed first the fan motor may tilt down or fall and...

Страница 11: ...al Procedure 9 6 Release the fan motor lead wire from the 2 hooks and pull the fan motor out When reassembling put the fan motor lead wire through the back of the fan motor so as not to be entangled w...

Страница 12: ...emove the top panel and the front panel according to the Removal of Outer Panels Colors of the connection wires are as follows 1 black 2 white 3 red yellow green 1 2 Remove the 4 screws and disconnect...

Страница 13: ...the service monitor PCB 1 Release the harness from the hook 2 Disconnect the connectors S52 S102 from the service monitor PCB 3 Remove the service monitor PCB 4 Remove the screw of the terminal board...

Страница 14: ...de S20 electronic expansion valve S40 overload protector S80 four way valve coil S90 thermistors The cooling only models do not have the harness for S80 When reassembling insert each clamp into the ho...

Страница 15: ...ten the 2 hooks and release the main PCB from the ditch of the front side 6 Disconnect the harnesses S10 AC2 while lifting the main PCB 7 Disconnect the connectors S51 S101 Step Procedure Points Main...

Страница 16: ...SPM S33 S34 on MID S40 overload protector S51 S52 on service monitor PCB S71 S72 on MID S80 four way valve S90 thermistors S91 radiation fin thermistor S101 S102 on service monitor PCB H1 H2 diode br...

Страница 17: ...Si00 876 Removal of PCBs Electrical Box Removal Procedure 15 10 Release the clamp with pliers 11 Disconnect the 2 connectors for the reactor Step Procedure Points R17066 R17067...

Страница 18: ...al Procedure 12 Pull the clamp and draw the thermistor harness out from the back of the electrical box 13 Remove the screw of the electrical box 14 Lift up and remove the electrical box Step Procedure...

Страница 19: ...to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Release the clamp with pliers 2 Remove the 2 screws of the partition plate The par...

Страница 20: ...f Reactor Si00 876 18 Removal Procedure 3 Lift up the partition plate and remove it 4 Remove the screw Slide the reactor upward and remove it from the partition plate Step Procedure Points R16459 R272...

Страница 21: ...stor ASSY Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical box according to the Removal of Electrical Box 1 Release the discharge pipe thermistor Be car...

Страница 22: ...ket carefully 1 Remove the sound blanket top upper 2 Remove the sound blanket top lower Some models do not have the sound blanket top lower 3 Remove the sound blanket outer 4 Remove the sound blanket...

Страница 23: ...quickly when no nitrogen gas can be used 2 It is required to prevent the carbonization of the oil inside the four way valve and the deterioration of the gaskets affected by heat For the sake of this w...

Страница 24: ...If the refrigerant gas leaks during work ventilate the room If the refrigerant gas is exposed to flames toxic gas may be generated Caution From the viewpoint of global environment protection do not d...

Страница 25: ...cedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the terminal cover 2 Disconnect the lead wires of th...

Страница 26: ...ed Warning Since it may happen that the refrigerant oil in the compressor catches fire prepare wet cloth so as to extinguish fire immediately Caution From the viewpoint of global environment protectio...

Страница 27: ...Revision History Month Year Version Revised contents 06 2013 Si00 876 First edition...

Страница 28: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...