![Daikin RKC18QV2S Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/daikin/rkc18qv2s/rkc18qv2s_service-manual_4702939021.webp)
Si001658EA
Four Way Valve
Removal Procedure
19
2
Remove the terminal
cover.
3
4
Remove the protection
bushing.
Disconnect the
compressor lead wires
(U, V, W) and the
overload protector.
5
6
7
Cut the clamp.
Remove the putty.
Heat up the 2 brazed
parts and remove the
four way valve.
Step
Procedure
Points
Terminal cover
(R23741)
Protection bushing
U (red)
Overload
protector
V (yellow)
W (blue)
(R23738)
Four way valve
Clamp
Putty
Brazed part
(R23742)