4 Energy saving tips
Operation manual
8
RGSQH10S18AA9W
ROTEX HPU ground
4P353880-1A – 2015.10
INFORMATION
Depending on the selected installer settings, settings will
be visible/invisible.
3.8
Installer settings: Tables to be
filled in by installer
3.8.1
Quick wizard
Setting
Default
Fill in…
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
0 (No)
Space heating settings [A.2.1]
Unit control method
0 (LWT control)
User interface location
1 (In room)
Number of LWT zones
0 (1 LWT zone)
Pump operation mode
1 (Sample)
Domestic hot water settings [A.2.2]
DHW pump
0 (No)
Thermostats [A.2.2]
Contact type main
1 (Thermo ON/
OFF)
Contact type add.
1 (Thermo ON/
OFF)
External sensor
0 (No)
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
0 (No)
Alarm output
0 (Normally open)
Demand PCB [A.2.2.7]
Demand PCB
0 (No)
Energy metering [A.2.2]
External kWh meter 1
0 (No)
External kWh meter 2
0 (No)
Capacities (energy metering) [A.2.3]
BUH: step 1
3 kW
BUH: step 2
3 kW
Auto emergency [A.5.1.2]
Emergency
Manual
INFORMATION
Auto emergency: By default, backup heater operation
during emergency operation is NOT allowed. This means
that when a heat pump failure occurs the user needs to
manually confirm that backup heater may operate during
emergency. If the house is unattended for longer periods,
we recommend that setting [A.5.1.2] Emergency shall be
set to Automatic.
3.8.2
Space heating control
Setting
Default
Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
1 (Weather dep.)
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
1 (Weather dep.)
Leaving water temperature: Delta T source [A.3.1.3]
Heating
8°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
0 (No)
Setting
Default
Fill in…
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
0 (Quick)
3.8.3
Domestic hot water control [A.4]
Setting
Default
Fill in…
Type
1 (
sched.)
Maximum setpoint
60°C
3.8.4
Contact/helpdesk number [6.3.2]
Setting
Default
Fill in…
Contact/helpdesk number
—
4
Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature.
Example:
When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode.
Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about DHW tank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW tank to a preset value (Storage
comfort = higher DHW tank temperature) during the night,
because then space heating demand is lower.
▪ If heating up the DHW tank once at night is not sufficient,
program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example:
After installation, lower the DHW tank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary.
Example:
In the morning and evening.
5
Maintenance and service
5.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to: