![Daikin RE50KV1 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/daikin/re50kv1/re50kv1_service-manual_501753007.webp)
Si011192
Removal of Outdoor Fan / Fan Motor (Pattern 1)
Removal Procedure
5
6
7
8
Remove the nut and
remove the outdoor fan.
Unfasten the 2 hooks.
Release the fan motor
lead wire.
Remove the 4 screws
and remove the fan
motor.
When reassembling, fit the
lower hooks into the bottom
frame.
Nut size: M6
Align the
mark of the
outdoor fan with the D-cut
section of the motor shaft
when reassembling.
Screw size: M4 × 16
Step
Procedure
Points
(R15385)
(R15160)
Outdoor
fan
D-cut
(R15161)
Hook
Fan motor
(R15162)
10 mm
(R17447)