Removal of Outdoor Fan / Fan Motor (Pattern 1)
Si011192
4
Removal Procedure
2. Removal of Outdoor Fan / Fan Motor (Pattern 1)
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Pull out the 2 terminals
[A1] [B1] from the fan
capacitor (C12R).
Fan capacitor (C12R)
Magnetic contactor (K1M)
2
Pull out the terminal [5]
from the magnetic
contactor (K1M).
3
Release the fan motor
lead wire from the hook.
4
Remove the screw of
the fan motor fixing
plate.
5
Remove the fan motor
fixing plate.
Be careful so as not to
damage the top part of the
outdoor heat exchanger fins.
Put the fan motor lead wire
through the back of the fan
motor when reassembling so
as not to be entangled with
the outdoor fan.
(R16854)
Fan capacitor
Magnetic
contactor
Fan motor lead wire
to fan motor:
red
to fan motor: white
to magnetic
contactor: red
B1B2
A1A2
(R17464)
to fan motor: black
(R15160)
(R16855)
Fan motor
fixing plate
(R16856)
(R3249)
Lead wire
Outdoor fan