Страница 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXG09HVJU FTXG12HVJU FTXG15HVJU English Fran ais...

Страница 2: ...ration 10 HEATING Operation 11 AUTO Operation 12 FLASH STREAMER AIR PURIFYING POWERFUL Operation 13 Adjusting the Airflow Direction and Rate 14 COMFORT AIRFLOW COOLING BREEZE Operation 15 TIMER Operat...

Страница 3: ...er there is the danger of oxygen deficiency which could lead to an asphyxiation hazard resulting in serious injury or death Be sure to ventilate the room sufficiently to avoid this hazard Safely dispo...

Страница 4: ...outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smok...

Страница 5: ...operation Push once again to stop it Multi monitor lamp The lamp color changes according to the operation HEATING RED COOLING GREEN SARARA DRYING DRY COOLING YELLOW The lamp color also changes accordi...

Страница 6: ...lytic air purifying filter black Page 24 27 Air filter light blue Page 23 Refrigerant piping and inter unit wiring Drain hose Drains water coming from the indoor unit Outdoor temperature sensor It det...

Страница 7: ...ure Page 19 TEMPERATURE adjustment buttons Changes the temperature setting POWERFUL button Makes cooling or heating more powerful Canceled in 20 minutes Page 13 DISPLAY LCD Displays the current settin...

Страница 8: ...SET UP CHILD LOCK button COMFORT SLEEP button Controls the room temperature to support comfort sleep and pleasant wake up Page 17 SET UP button Sets the unit operation and remote controller display a...

Страница 9: ...or approximately 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries with new size AAA LR03 alkaline...

Страница 10: ...C 28 C For heating 68 F 72 F 20 C 22 C Notes on the operating conditions The air conditioner always consumes a small amount of electricity even while it is not operating If you are not going to use th...

Страница 11: ...OFF HIGH STD LOW CONT HIGH STD LOW CONT GREEN YELLOW NOTE Note on ON OFF button Pressing will start the same operation as the last time Note on COOLING operation This air conditioner cools the room by...

Страница 12: ...pacity becomes smaller in lower outdoor temperatures If the heating effect is insufficient it is recommended to use another heating appliance in combination with the air conditioner The heat pump syst...

Страница 13: ...ording to the operation selected by the air conditioner will light up To change the temperature setting 64 F 86 F 18 C 30 C To stop operation Press The multi monitor lamp of the unit will go off NOTE...

Страница 14: ...ancel POWERFUL operation Press again The operation mode goes back to the previous one The multi monitor lamp on the unit also goes back to the previous color NOTE Notes on FLASH STREAMER AIR PURIFYING...

Страница 15: ...A DRYING DRY COOLING AUTO COOLING HEATING FLASH STREAMER AIR PURIFYING 5 levels of airflow rate settings from to plus are available NOTE If the unit is operated with the louvers pointed down and stopp...

Страница 16: ...ak airflow rate may not cool or heat the room sufficiently Indoor unit quiet operation When the airflow is set to the noise from the indoor unit will become quieter Operating mode Airflow rate setting...

Страница 17: ...s the unit to automatically change the set temperature 1 hour later to prevent the room from becoming too cold or too hot Turns up 1 F 0 5 C during COOLING or DRY COOLING and turns down 3 6 F 2 C duri...

Страница 18: ...comfortable to some extent before sleep Recommended set temperature COOLING 79 F 84 F 26 C 29 C HEATING 68 F 77 F 20 C 25 C Too low set temperature may cause you to get chilled while asleep NOTE Note...

Страница 19: ...F C Switches the temperature between Celsius and Fahrenheit MONITOR BRIGHTNESS HIGH LOW OFF Changes the brightness of the indoor unit display BEEP volume LOW HIGH OFF Sets the receiving tone volume CO...

Страница 20: ...LING or SARARA DRYING operation or lower in HEATING operation especially if frost has accumulated on the outdoor unit due to the effects of the air blown from the outdoor unit or the temperature of th...

Страница 21: ...ote controller toward the main unit with powered off Indication disappears NOTE CLEAN FILTER sign will appear after about 340 hours of operation CLEAN STREAMER sign will appear after about 1800 hours...

Страница 22: ...Placing a finger on the panel tab on either side of the front panel Front panel 2 Remove the front panel Spread out the shaft hole and remove the front panel shaft Both left and right sides Shaft hole...

Страница 23: ...with a soft cloth Wiping with a hard cloth may scratch it Cleaning for each case Wipe it with a soft cloth soaked in water Only neutral detergent may be used In case of washing the front panel with w...

Страница 24: ...er Wash the air filters with water or clean them with vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade 4 S...

Страница 25: ...tion Tab Knob Deodorizing filter for streamer 3 Pull out the streamer unit Hold the center of the handle and pull out in a downward direction 4 Remove the Titanium apatite photocatalytic air purifying...

Страница 26: ...he Titanium apatite photocatalytic air purifying filter Insert the 2 upper tabs on the Titanium apatite photocatalytic air purifying filter into the guides on the main unit and then hook up the 2 lowe...

Страница 27: ...o drain away water Streamer unit 1 Soak in warm water with mild liquid detergent for about 1 hour With detergent Soak for about 1 hour Observe the volume of mild liquid detergent specified in the inst...

Страница 28: ...es Dispose a used filter as burnable waste material paper Titanium apatite photocatalytic airpurifying filter Once in about 3 years Discharge the 4 tabs of the filter frame and replace the filter with...

Страница 29: ...ck that the drain comes smoothly out of the drain hose during COOLING or DRY operation If no drain water is seen water may be leaking from the indoor unit Stop operation and consult the service shop i...

Страница 30: ...ost operation In COOLING operation Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when the air in the room...

Страница 31: ...the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the airflow rate and the air direction set appropriately Is the ventilator fan spinning An abnormal funct...

Страница 32: ...An object or water got into the unit The safety breaker a fuse or the ground leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smel...

Страница 33: ...ZE UP PROTECTOR A6 FAN MOTOR FAULT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C7 FRONT PANEL OPEN CLOSE FAULT C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING FAULT...

Страница 34: ...3P226009 1A M07B240A 1211 HT Two dimensional bar code is a code for manufacturing...