3
Indoor/outdoor Unit Installation Diagram
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
.,-
.,.--_.. -
r
@Moi..ntingplatefodngscrewM4�25L(Jpc:s.)
·:f
m
T
�oonlingplatefixlng.,,rewM4":2Ii(7pcs.)
For type (i)@@@) (Refer table no. 4)
For type@ (Refer table no. 5)
Note: Before installation, mounting plate size & shape must be matched with mounting plate available in the unit, then accordingly follow the installation instruction.
30mm or more
from ceiling
50mm o
r
more from�
Flaps (horizontal blades)
(on boths
l/lf!t
d
e
s)
7/iJ#
Service lid
00 00
Air filters
Accessory filter
�-:
Capacity Class (kV'/')
::.4.214.2 to.: 5.515.5 to.: 6.516.Sto .: 7.1
�\
Install the (fl) Accessory filter
• Be sure to add the proper amount of
additional refrigerant. Failure to do so may
result in reduced performance.
Max. allowable piping length {m)
Min. allowable piping lergth (m)
Max. allowable piping height (m)
Additional refrigerant required for refrigerant
pipeexceeding1Cminlergth
Gas pipe Diameter (mm)
LiquidpipeDiameter(mm)
•• The suggested shortest pipe length is 3m,
in order to avoid noise from the outdoor unit
and vibration.
(Mechanical noise and vibration may occur
depending on how the unit is installed and
the environment in which it is used.)
Dimensions of ODU installation leg*
Type
Applicabel unit size•
A
B
C
[HJ X [W] X [D]
(j)
418x695x244
467
119.5
287
(j)
550 X 675 X 284
470
97
308
(jJ
550 X 765 X 285
573.5
131
326
@)
595 X 845 X 300
574
105.5
311
®
695 X 930 X 350
610
175
367
• Unit size available on name plate.
Table No. 3
In sites with poor drainage, use
block bases for outdoor unit.
Adjust foot height until the unit is
leveled. Otherwise, water leakage
or pooling of water may occur.
Note: All shapes or appearance may vary from actual parts.
15 I
20
I
25
I
30
3
12 I
16
I
2JJ
I
20
20glm
9.5 I
12.7
I
15.9
,.,
Allow 300mm of
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that
no gap is left in the
insulation pipe's cut line.
©
Wireless remote
� controllereldentical Image)
�
Berorn scrnw;,g the
Q)remote controller
holder to the wall,
make sure that
control signals are
properly received
by
:(1
indoorunit.
(r--tff�
/Q)R
e
mote
V --�
����
lier
®
Remote controller holder
fixing screw M3 x 20L
Allow space
for piping and
electrical