background image

13

 / English

Care and Cleaning

CAUTION

When cleaning the unit, be careful not to cut your hands with the 
opposing pole plate or ionizer wires.
 (It is safer to use rubber gloves.)

When cleaning the unit, be careful not to cut the ionizer wires.

Be sure to do in a shower-proof place such as bathroom or sink in a 
kitchen.

Use only specified volume of liquid mild detergent.

Do not use powder detergent or alkaline detergent and scrub with 
hard sponge. Distortion or damage to the equipment may result.

„

„

„

„

Cleaning the plasma ionizer

1) Ionized wire (8 pieces)

• Clean off the ionizer wires and peripheral resin part with a soft 

cloth. 

2) Streamer discharger

• Clean off the internal resin part with a soft cloth. 

(For removal, see page 11.) 

3) Ionizing frame

• Clean off the resin part with a soft cloth. 
• Use a cotton bud to wipe off dirt of odd-shaped area where 

your finger does not reach. 

• Be careful not to leave bits of tissue. Malfunction may result. 

NOTE

If the ionizer wires are cut;

Replacement is necessary. Contact your dealer.

2) Streamer discharger

1) Ionized wire

3) Ionizing frame

* Gently wipe off the ionizer wires. 

Pulling hard may cut them.

: Resin part *1

*1 Wipe off only the resin part. 
*2 Do not touch the discharge needle. 

Bending the needle will reduce 
deodorizing performance.

Discharge 
needle
*2

Cotton bud

* Use a cotton bud to wipe off dirt 

of odd-shaped area. 

01_EN_3P167171-1A.fm  Page 13  Tuesday, October 18, 2005  4:14 PM

Содержание MC707VM-S

Страница 1: ...OPERATION MANUAL MODEL MC707VM S MC707VM W PHOTOCATALYTIC AIR PURIFIER English Deutsch Français Nederlands Español Italiano ΕλληνικÜ Portugues Рóссêий ...

Страница 2: ...riate Use Select a place where air is circulated throughout the room The air blows slightly slant to the right When you want to remove house dust setting up the air purifier in low rooms is effective When you want to remove cigarette smoke setting up the air purifier in high rooms is effective Placing the air cleaner on the other side of the air conditioner will improve air circulation effect effe...

Страница 3: ...ption sensitivity and discolor the casing Do not use in the place of kitchen fans or cooker hood fans Adverse conditions of use can shorten service life of the prelilter and ion filter as well as lead to equipment damage Prevent combustibles hair sprays etc sparks and incense from being drawn into the unit Such substances can cause fire Do not insert fingers or foreign objects into the inlet or ou...

Страница 4: ...e air back to the room Note cannot be washed with water 12 Filter container Six replacement pleated filters are included 13 Ventilation fan 14 Air inlet 15 Remote controller storage slot Stores the accessory remote controller 16 Handle Use when moving the main unit 17 Air outlet 18 Negative ionization assembly Generates negative ions Functions to combine positively charged toxic substances in a ro...

Страница 5: ...w Lit during automatic operation 5 Airflow rate indicator green page 7 Lit by the set airflow rate setting The air volume lamp is on during automatic or manual operation 6 Turbo mode indicator green page 7 Lit during turbo mode 7 Pollen mode indicator page 7 Lit during pollen mode 8 Negative ion mode indicator page 7 Indicates during negative ion operation 9 OFF timer setting indicator yellow page...

Страница 6: ...he manufacturing date of the air purifier A replacement target is approximately 1 year but if the reception becomes difficult replace the batteries with new coin type battery CR2025 Coin type battery close to the recommended usage period may need to be replaced soon In order to prevent malfunctions or injuries due to leaking or explosions be sure to remove the coin type battery when the unit will ...

Страница 7: ...ter Hook the holes 2 locations of the bio antibody filter on the hooks 2 locations of the plasma ionizer 3 Restore the pre filter Hook the bottom part of the pre filter on the bottom hooks 2 locations of the plasma ionizer and then insert it into the left and right hooks 4 locations 4 Restore the front panel Hook the top hooks 3 locations of the front panel on the grooves on top of the main unit a...

Страница 8: ...e can be changed if the button is pressed while the timer is operating 8 When you want to change the brightness of the photo operation lamp and clean monitors Press the BRIGHTNESS button Each time it is pressed the display will switch as shown below Only set to OFF when you are concerned about light coming from the main unit such as when sleeping The photo operation will stop simultaneous with the...

Страница 9: ... shock or malfunction may occur Cleaning the air inlet for the dust odor sensor Clean dusts clogged in the air inlet for the dust odor sensor Use crevice nozzle of a cleaner for cleaning Cleaning the front panel Wipe off the dirt with a cloth or tissue slightly soaked with water In the case of heavy dirt wipe it off with a cloth soaked with mild detergent CAUTION Do not use hard sponge Scratch may...

Страница 10: ...t dry at a location directly exposed to the sun Do not clean with water hotter than 50 C Do not burn with fire Color changes or deformation may occur and the unit may become unusable Replacing the bio antibody filter The bio antibody filter should be replaced around once a year 1 Remove the front panel See the left figure 2 Remove the pre filter See the left figure 3 Replace the bio antibody filte...

Страница 11: ...ain unit display Press the reset switch with a sharp material such as a tooth pick to turn off the replacement sign It will beep NOTE Replace a pleated filter Contact your dealer for replacement pleated filter It is not necessary to replace a pleated filter until the replacement sign turns on or blinks When the replacement sign turns on replace a filter even though it is not dirty Apparent dirt is...

Страница 12: ...ore cleaning and be careful not to cut your hands with the opposing pole plate or ionizer wires It is safer to use rubber gloves CAUTION There are ionizer wires at back of the opposing pole plate When attaching or removing be careful not to cut them Cleaning sign blinks if operated while the ionizer wires are cut The dust elimination efficiency deteriorates while the sign is blinking If the ionize...

Страница 13: ...ge Distortion or damage to the equipment may result Rinse with running water Soak in water or warm water to remove detergent about 30 minutes Caution Soak well as cleaning sign may be on even after cleaning if any detergent remains Rinse with running water and then dry Caution Be careful not to leave bits of tissue such as cloth Malfunction may result Dry in the breezy shade about 1 day Caution Do...

Страница 14: ...ires and peripheral resin part with a soft cloth 2 Streamer discharger Clean off the internal resin part with a soft cloth For removal see page 11 3 Ionizing frame Clean off the resin part with a soft cloth Use a cotton bud to wipe off dirt of odd shaped area where your finger does not reach Be careful not to leave bits of tissue Malfunction may result NOTE If the ionizer wires are cut Replacement...

Страница 15: ...nizer 2 Attach the opposing pole plate while opening the knobs one at a side of the plasma ionizer 3 Insert securely until it clicks 4 Attach another side of the opposing pole plate 2 Attach the streamer discharger 1 Insert bottom of the streamer discharger to the ionizer frame 2 Insert top of the streamer discharger 3 Confirm if it is attached securely Insert downward Open ...

Страница 16: ...is performed during the settings the settings will not be correct When the sensitivity is set high it will become difficult for the sensor lamp to go out Optional accessories For replacement pleated filter and bio antibody filter contact your dealer If used with dirty parts Cannot obtain air clean effect Cannot obtain deodorization effect Odor may arise Disposal requirements Your Daikin product is...

Страница 17: ...ime Is there any foreign matter in the air outlet Remove the foreign matter For other cases contact your dealer Air does not come out Cleaning effect is not obtained Is the unit installed at a location where the flow does not pass or are there obstructions close to the unit Remove the obstruction Is there too much dust in the pre filter or pleated filter Clean or replace pages 5 6 9 Is too much od...

Страница 18: ...Umeda Center Bldg 4 12 Nakazaki Nishi 2 chome Kita ku Osaka 530 8323 Japan 2SB63475 11E MC707VM S MC707VM W Noboru Murata Manager Quality Control Department Shiga 1st of Nov 2005 ...

Страница 19: ... 0511 HT 3P167171 1A M05B061A ...

Отзывы: