Operation Manual
SiBE81-623A
22
Photocatalytic Air Purifiers
11
Care and Cleaning
3. Remove the bio-antibody filter.
• Remove the bio-antibody filter from hooks (2 locations) at top of
the plasma ionizer.
4. Remove the plasma ionizer.
• Holding the handle, lift towards yourself and remove from the top
2 hooks.
5. Remove the opposing pole plates at back of the plasma
ionizer.
• Open the knob of the ionizer frame and hold up the opposing pole
plate to remove.
6. Remove the streamer discharger.
• Insert your finger into the hole on top (hole with
mark) and
then gently pull up the streamer discharger.
Clean the plasma ionizer
(If “cleaning sign” on the main unit display blinks)
CAUTION
•
Stop operation before cleaning and be careful not to cut your hands
with the opposing pole plate or ionizer wires.
(It is safer to use rubber gloves.)
There are ionizer wires at back of the opposing pole
plate. When attaching or removing, be careful not to cut
them.
• “Cleaning sign” blinks if operated while the ionizer wires are cut.
The dust elimination efficiency deteriorates while the sign is
blinking.
• If the ionizer wires should be cut, replacement is necessary.
Contact your dealer.
Plasma ionizer
Hooks
(one left and one right)
Knob
Open
Opposing
pole plate
Ionizing frame
Ionized wire
Be careful not
to catch in the
internal ionizer
wires.
It is easier to
remove if lifted
from outside.
Streamer discharger
Blink
Plasma ionizer
3) Streamer discharger
4) Opposing pole plates
1) Ionizing frame
2) Ionized wire
CAUTION
Bio-antibody filter
Top hooks (2 locations)