English /
4
■
■
■
■
Main unit display
1 Air intake for dust sensor
Air is taken in from here and the dust sensor detects the dirty state
of the air.
2 Clean monitor (Dust)
Detects the dirty state of the air and indicates the results.
• For the following case, only the green lamp is lit for the initial 7
seconds without regard to how dirty the air is.
• Operation directly after setting the front panel plasma ionizer
• Operation directly after inserting the power plug
3 Automatic operation indicator
Lit during automatic operation.
4 Airflow rate indicator
(Page 7)
Lit by the set airflow rate setting.
5 Pollen mode / turbo mode indicator
(Page 7)
Lit during pollen and turbo mode.
6 Photo operation lamp
(Page 7)
Lit during photo operation.
7 Receiver
Receives signals from the remote controller.
8 Operation switch / stop button
Each time this button is pressed, the operation mode switches as
shown below.
* During automatic operation the airflow rate at that time will also be
lit.
9 Child lock lamp
(Page 7)
Lit during child lock.
10 Negative ion mode indicator
(Page 7)
Indicates during negative ion operation.
11 OFF timer setting indicator
(Page 7)
Indicates the set OFF timer time.
Indicates the time passed as well as the remaining time after the
setting.
12 Clean indicator
(Page 9)
Flashes during cleaning period of plasma ionizer to notify that clean-
ing is necessary.
13 Filter roll / Replace indicator / Reset button
When the replacement time for the filter roll arrives, this lamp lights
and if the time passes, it will flash.
After replacement, press the reset button. (Page 9)
14 Air intake for odor sensor
Air is taken in from here and the odor sensor detects the odor state.
15 Clean monitor (Odor)
Detects changes to odors and indicates the results.
• Reactions to sudden temperature/humidity changes and odorless
gas (carbon monoxide) may occur.
• There may not be any reaction for a uniform case without any
changes to the intensity of the odor.
• There may be no reaction to pet odors or garlic odors.
• Different people have different sensitivity to odors so you may not
notice an odor even though the lamp is green.
• For the following case, only the green lamp is lit for the initial
1 minute. This state is the standard value of the odor sensor
sensitivity.
• Operation directly after setting the front panel plasma ionizer
• Operation directly after inserting the power plug
3
4
5
6
11
1
2
8
13
9
7
14
10
12
15
Dust
Low
Green
Green
Yellow
Green
Yellow
Orange
Green
Yellow
Orange
Red
High
Indicator
Off
On
(Automatic)
LL (Quiet)
L (Low)
M (Standard)
(Stop)
(Pollen)
HH (Turbo)
H (High)
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
Odor
Weak
Green
Green
Yellow
Green
Yellow
Orange
Green
Yellow
Orange
Red
Strong
Indicator
Off
On
01_EN_3P068886-5G.fm Page 4 Wednesday, December 4, 2002 2:34 PM
Содержание MC704VM
Страница 14: ... 0212 HT 3P068886 5G M02B140 ...