background image

21

About the Indicator Lamps

Troubleshooting

Operating/Indicator panel

Check the indicator lamps and respond as indicated below.

Indicator lamp

Cause/Solution

Odour sensor lamp is 

blinking.

This lamp blinks if the deodorising filter unit has become detached or is not attached properly.

 

Attach the deodorising fi lter unit properly. 

 

Page 18

Streamer sensor lamp is 

blinking.

It is time to replace the streamer unit. 

 

Page 19

All 3 MODE lamps are 

blinking simultaneously.

An electrical component is faulty.

 

Contact the place of purchase.

AUTO FAN MODE lamp 

is blinking.

All 4 FAN lamps are 

blinking simultaneously.

Are the pre-fi lter, outfl ow grille, 
and dust collection fi lter attached?

These lamps may blink if the unit 
is operated without a part 
attached.

 

„

If all parts are attached
An electrical component is faulty.

 

Contact the place of purchase.

 

„

If one or more components are not attached

Remove the power supply plug, reattach the parts 

and then turn the unit on again.

Is there a buildup of dust on the 

pre-filter?

 

„

If there is no dust buildup
An electrical component is faulty.

 

Contact the place of purchase.

 

„

If there is a dust buildup

Remove the power supply plug, clean the pre-fi lter 

and then turn the unit on again. 

 

Page 17

Is the air outlet blocked?

 

„

If the air outlet is not blocked

An electrical component is faulty.

 

Contact the place of purchase.

 

„

If the air outlet is blocked

Remove any obstacles blocking the air outlet and 

then turn the unit on again.

These lamps may blink if there is a sudden drop in voltage. 

 

Page 24

01_EN_3P549981-1B.indd   21

12/12/2019   2:08:37 PM

Содержание MC55VBFVM

Страница 1: ...MANUAL Air puri er Thank you for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep...

Страница 2: ...MII 2010 10 Results Skin moisture content increased 1 8 times over approx 120 minutes Actual effects vary by operating environment and usage patterns Streamer discharge decomposes adsorbed odour Elimi...

Страница 3: ...seful Functions Operating the Unit in a MODE 11 AUTO FAN ECONO ANTI POLLEN Using the Child Proof Lock 13 Adjusting Indicator Lamp Brightness 13 Operation Using the Air Purifying Operation 10 Changing...

Страница 4: ...ric shock short circuiting or fire due to overheating may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to...

Страница 5: ...r mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children shoul...

Страница 6: ...unit Inside the air outlet Dust PM2 5 sensor Inside the air inlet left side Page 6 15 17 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Pa...

Страница 7: ...ies by person in some cases an odour may be sensed even when the lamp is green If the odour bothers you switch to manual airflow rate and select a high airflow rate Page 10 The ambient odour level in...

Страница 8: ...ine Remote controller FAN MODE button Press to cycle between FAN settings and MODEs Page 10 12 ON OFF button Press to turn the power ON or OFF Page 10 ON OFF button Press to turn the power ON or OFF P...

Страница 9: ...ble and is not harmful to your health This product cannot eliminate all of the toxic substances in tobacco smoke carbon monoxide etc Do not use in the following places Places exposed to direct sunligh...

Страница 10: ...About the battery Keep batteries out of reach of children In the event that batteries are swallowed go immediately to the nearest medical emergency services To avoid possible injury or damage from ba...

Страница 11: ...ed for use during sleep hours To quickly eliminate odours from a room it is recommended that the FAN setting be set to Standard or above otherwise deodorising capacity is reduced Turbo The ambient air...

Страница 12: ...our needs Airflow is adjusted automatically when the unit is running in a MODE Remote controller Press Each press cycles between the MODE lamps green ECONO ANTI POLLEN AUTO FAN Unit Press Each press c...

Страница 13: ...igarette was smoked immediately after the unit was turned on Power saving mode Monitoring mode FAN setting switches automatically between Quiet and Low Streamer OFF The fan starts and stops periodical...

Страница 14: ...Note If the unit is unplugged when Child proof lock is active Child proof lock is turned off The Child proof lock lamp orange lights up when the function is active Adjusting Indicator Lamp Brightness...

Страница 15: ...r operation is OFF Note It is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low Settings are remembered even if the unit is unplugged Blinking Lit up W...

Страница 16: ...FAN lamps allowing you to change the sensitivity To set sensitivity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard...

Страница 17: ...mp ON or OFF The FAN lamp Quiet will remain lit up To turn Monitoring mode ON Turn on the ECONO MODE lamp To turn Monitoring mode OFF Turn off the ECONO MODE lamp Setting at time of purchase ON OFF Se...

Страница 18: ...bud or hard brush etc Partial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip eit...

Страница 19: ...ds on usage patterns and the location of the unit If the unit is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on testin...

Страница 20: ...ed Pulling forcibly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Attach the...

Страница 21: ...e battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Hg mercury 0 0005 Disposal of this product must be done in accordance with relevant local and...

Страница 22: ...on filter attached These lamps may blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more compon...

Страница 23: ...sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if dirt build...

Страница 24: ...range protection 180V 264V Unit will not operate Is the streamer unit cover attached If it is not attached the safety switch will engage and the unit cannot operate Install the streamer unit cover pr...

Страница 25: ...g a dry cotton bud or similar Page 17 Is the pre filter dirty Page 17 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on There is an odour bu...

Страница 26: ...is being emitted Is the air outlet or an air inlet blocked If they are not blocked an electrical component is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway th...

Страница 27: ...und dB 53 39 29 19 Airflow rate m h 330 192 120 66 Coverage area m 41 1 External dimensions mm 500 H 270 W 270 D Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicable...

Страница 28: ...The bar code is a manufacturing code 3P549981 1B M18B152B 1912 HT The two dimensional bar code is a manufacturing code...