background image

14

Advanced Settings

If the hissing sound generated by the streamer discharge or the smell of ozone 

bother you

*Setting at time of purchase

Streamer Output Settings

Setting procedures  

Remote controller 

  

 

Hold down 

 and 

 for about 3 seconds when the unit is off.

• 

Each time

 

 and 

 

are held down for about 3 seconds, the setting switches between Regular and Low.

[When the setting is changed to Low]
A short beep sounds and the streamer lamp blinks for about 5 seconds.

[When the setting is changed to Regular]

A short beep sounds and the streamer lamp lights up for about 5 seconds.

 

„

Operation status of streamer

  

Regular

Low

*The streamer operation status ON–OFF 

means that the streamer turns ON and OFF 
automatically depending on the degree of air 
impurity and FAN setting.

FAN

Quiet, Low

ON–OFF*

OFF

Standard

ON–OFF*

Turbo

ON

ON

MODE

AUTO FAN, ANTI-POLLEN

ON–OFF*

ON–OFF*

ECONO

OFF

FAN/MODE setting

Streamer output setting

• 

The streamer lamp turns off when streamer operation is OFF.

Note

•  It is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low.
• 

Settings are remembered even if the unit is unplugged.

Blinking

Lit up

When you want to turn off active plasma ion output

*Setting at time of purchase

Active Plasma Ion Output Settings

ON*

OFF

Setting procedures  

Remote controller 

  

  Hold down 

 and 

 for about 3 seconds when the unit is off.

• 

Each time 

 and 

 are held down for about 3 seconds, the setting switches between ON and OFF.

[When the setting is changed to OFF]
A short beep sounds and the dust lamp and odour sensor lamp blink green for about 5 
seconds.

[When the setting is changed to ON]
A short beep sounds and the dust lamp and odour sensor lamp light up green for about 5 
seconds.

Blinking

Lit up

Note

• 

Settings are remembered even if the unit is unplugged.

• 

If set to OFF, active plasma ion discharge stops, however, dust and odour removal continues.

• 

If the smell of ozone bothers you, set active plasma ion output to OFF.

•  If the smell of ozone continues to bother you, even after output has been set to OFF, set streamer output to Low.

Regular*

Low

ON*

OFF

Advanced Settings

01_EN_3P549981-1B.indd   14

12/12/2019   2:08:28 PM

Содержание MC55VBFVM

Страница 1: ...MANUAL Air puri er Thank you for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep...

Страница 2: ...MII 2010 10 Results Skin moisture content increased 1 8 times over approx 120 minutes Actual effects vary by operating environment and usage patterns Streamer discharge decomposes adsorbed odour Elimi...

Страница 3: ...seful Functions Operating the Unit in a MODE 11 AUTO FAN ECONO ANTI POLLEN Using the Child Proof Lock 13 Adjusting Indicator Lamp Brightness 13 Operation Using the Air Purifying Operation 10 Changing...

Страница 4: ...ric shock short circuiting or fire due to overheating may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to...

Страница 5: ...r mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children shoul...

Страница 6: ...unit Inside the air outlet Dust PM2 5 sensor Inside the air inlet left side Page 6 15 17 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Pa...

Страница 7: ...ies by person in some cases an odour may be sensed even when the lamp is green If the odour bothers you switch to manual airflow rate and select a high airflow rate Page 10 The ambient odour level in...

Страница 8: ...ine Remote controller FAN MODE button Press to cycle between FAN settings and MODEs Page 10 12 ON OFF button Press to turn the power ON or OFF Page 10 ON OFF button Press to turn the power ON or OFF P...

Страница 9: ...ble and is not harmful to your health This product cannot eliminate all of the toxic substances in tobacco smoke carbon monoxide etc Do not use in the following places Places exposed to direct sunligh...

Страница 10: ...About the battery Keep batteries out of reach of children In the event that batteries are swallowed go immediately to the nearest medical emergency services To avoid possible injury or damage from ba...

Страница 11: ...ed for use during sleep hours To quickly eliminate odours from a room it is recommended that the FAN setting be set to Standard or above otherwise deodorising capacity is reduced Turbo The ambient air...

Страница 12: ...our needs Airflow is adjusted automatically when the unit is running in a MODE Remote controller Press Each press cycles between the MODE lamps green ECONO ANTI POLLEN AUTO FAN Unit Press Each press c...

Страница 13: ...igarette was smoked immediately after the unit was turned on Power saving mode Monitoring mode FAN setting switches automatically between Quiet and Low Streamer OFF The fan starts and stops periodical...

Страница 14: ...Note If the unit is unplugged when Child proof lock is active Child proof lock is turned off The Child proof lock lamp orange lights up when the function is active Adjusting Indicator Lamp Brightness...

Страница 15: ...r operation is OFF Note It is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low Settings are remembered even if the unit is unplugged Blinking Lit up W...

Страница 16: ...FAN lamps allowing you to change the sensitivity To set sensitivity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard...

Страница 17: ...mp ON or OFF The FAN lamp Quiet will remain lit up To turn Monitoring mode ON Turn on the ECONO MODE lamp To turn Monitoring mode OFF Turn off the ECONO MODE lamp Setting at time of purchase ON OFF Se...

Страница 18: ...bud or hard brush etc Partial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip eit...

Страница 19: ...ds on usage patterns and the location of the unit If the unit is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on testin...

Страница 20: ...ed Pulling forcibly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Attach the...

Страница 21: ...e battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Hg mercury 0 0005 Disposal of this product must be done in accordance with relevant local and...

Страница 22: ...on filter attached These lamps may blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more compon...

Страница 23: ...sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if dirt build...

Страница 24: ...range protection 180V 264V Unit will not operate Is the streamer unit cover attached If it is not attached the safety switch will engage and the unit cannot operate Install the streamer unit cover pr...

Страница 25: ...g a dry cotton bud or similar Page 17 Is the pre filter dirty Page 17 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on There is an odour bu...

Страница 26: ...is being emitted Is the air outlet or an air inlet blocked If they are not blocked an electrical component is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway th...

Страница 27: ...und dB 53 39 29 19 Airflow rate m h 330 192 120 66 Coverage area m 41 1 External dimensions mm 500 H 270 W 270 D Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicable...

Страница 28: ...The bar code is a manufacturing code 3P549981 1B M18B152B 1912 HT The two dimensional bar code is a manufacturing code...