background image

21

Troubleshooting

 

„

Air purifying function

Phenomenon

Check points

Air purifying capacity is reduced

Is the unit positioned in a place where airfl ow cannot reach or

surrounded by obstacles?

Choose a position that is obstacle-free and from where airfl ow can

reach all areas of the room.

Is the pre-fi lter or dust collection fi lter dirty?

Clean these parts.

 

 

Page 13, 14

The air outlet is emitting an odour

Is the deodorising fi lter dirty?

Clean these parts. 

 

Page 14

In some cases the air outlet may emit a slight odour as trace amounts of

ozone are generated. However, the amount is negligible and is not harmful

to your health.

Is the room fi lled with odours due to cooking or several people

smoking together etc?

The odour will gradually fade as the unit operates.

Have you moved the unit from another room?

The unit may emit the odour of the room in which it was used previously.
Let the unit run a while longer.

Is there anything in the room that is giving off an odour continuously?

(Paint, new furniture, wallpaper, sprays, cosmetics, chemicals)

As continuously emitted odours cannot be completely eliminated, you

should ventilate the room at the same time or run the unit in a well-
ventilated room for a short while.

No air is being emitted

Is the air outlet or an air inlet blocked?

If they are not blocked, the fan motor is faulty.

Contact the place of purchase.

 

„

Other

Phenomenon

Check points

The fan stops midway through unit 

operation

• When the unit switches to Monitoring mode during operation in ECONO

MODE, the fan turns on and off repeatedly. 

 

Page 10

Are the pre-fi lter, outfl ow grille, and dust collection fi lter attached

before the unit is operated?

The fan is confi gured to stop in order to protect electrical

components if a part is not properly attached.

If a part is not attached, unplug the unit and attach all parts before
turning the unit on again.

The sound of streamer discharge can 

no longer be heard

The streamer may cease operating depending on the degree of air impurity. 

 

Page 6

There is interference on our TV 

screen

Is the TV or radio positioned within 2m of the unit, or is an indoor

antenna positioned near the unit?

Are the power supply cord or antenna cable of the TV or radio routed

near the unit?

Keep the unit as far as possible from the TV, radio, or antenna.

Just inserting the power plug causes 

operation to start

Did you disconnect the power plug during a power failure, or when a

sudden voltage fl uctuation occurred, to move the unit or disconnect

the power plug during the last operation?

The auto-restart function automatically resumes operation.

Troubleshooting

01_EN_3P484757-1D.indd   21

10/1/2018   11:37:19 AM

Содержание MC40YPVM

Страница 1: ...for purchasing this air puri er Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a sa...

Страница 2: ...olling PM2 5 These results were obtained in a 32m airtight space They are not demonstrable effects in customer environments Does not take into account in ow of new particles from outdoors owing to ven...

Страница 3: ...dvanced Settings Setting Dust PM2 5 Sensor Sensitivity 12 Operation Using the Air Purifying Operation 9 Changing the Airflow Rate 9 Maintenance Maintenance 13 Replacing the Streamer Unit 15 Separately...

Страница 4: ...g may result if the power supply plug is not firmly inserted Periodically wipe dust off the power supply plug with a dry cloth If the unit is not to be used for an extended period of time unplug the p...

Страница 5: ...safety Children should be supervised to ensure that they do not play with the appliance Persons who are heavily intoxicated or have taken sleep medication should not operate the unit An electric shock...

Страница 6: ...nside the air inlet left side Page 6 12 13 Model name Production no Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Parts Pre filter Page 13 Outflow grille Page 13...

Страница 7: ...rst minute after the unit is plugged in serves as the reference level upon which the sensitivity of the odour sensor is determined Insert the power supply plug when the air is clean odour free Odour s...

Страница 8: ...tatic noise to be emitted from nearby radios or stereos move the unit to at least 2m away from the device Keep cordless phones and radio controlled clocks away from the unit also Attention To avoid st...

Страница 9: ...Places with high levels of electromagnetic waves such as near an electromagnetic cooker speakers etc The unit may not function correctly Places exposed to soot conductive dust released by candles arom...

Страница 10: ...dard or above otherwise deodorising capacity is reduced Turbo The ambient air is quickly purified using a large airflow Recommended for use while you are cleaning up a room Using the Air Purifying Ope...

Страница 11: ...comparison to AUTO FAN MODE approx 9 2Wh power consumption in ECONO MODE approx 6 5Wh is approx 2 7Wh lower Test conditions operation in 10m2 area over 1 hour Assuming 1 cigarette was smoked immediate...

Страница 12: ...r switching to the desired brightness press and select FAN setting and MODE of operation again Note This function is useful if the lamps bother you during sleep hours etc The ON OFF lamp does not turn...

Страница 13: ...vity High Select the FAN lamp Turbo The sensor is highly receptive Setting at time of purchase The sensor is slightly receptive Standard Turbo Low High Normal Low To set sensitivity Low Select the FAN...

Страница 14: ...rtial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the indent in the pre filter and pull 1 Grip either end of the pre filte...

Страница 15: ...it is used daily in a home where 5 cigarettes are smoked a day the filter should be replaced about every 10 years Calculation based on testing method of Japan Electrical Manufacturers Association JEM1...

Страница 16: ...ly may cause damage 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Attach the new streamer unit...

Страница 17: ...f the dust collection filter made of polyester and polypropylene Maintenance When Not Using the Unit for Long Time Periods 1 Remove the power supply plug 2 Clean the parts Page 13 14 In particular com...

Страница 18: ...blink if the unit is operated without a part attached If all parts are attached An electrical component is faulty Contact the place of purchase If one or more components are not attached Remove the po...

Страница 19: ...ust PM2 5 sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace it if d...

Страница 20: ...hile the streamer is operating the streamer unit will emit a hissing sound when conducting streamer discharge Depending on usage conditions the sound may fall in volume or change to a crackling whirri...

Страница 21: ...a dry cotton bud or similar Page 13 Is the pre filter dirty Page 13 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on The PM2 5 INDICATOR l...

Страница 22: ...is being emitted Is the air outlet or an air inlet blocked If they are not blocked the fan motor is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway through uni...

Страница 23: ...Weight kg 6 8 Power supply cord length m 1 8 These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off approx 1W of power is consumed to run the micr...

Страница 24: ...3P629501 3 2020 08 17 For manufacturing use only 3P629480 14 F...

Отзывы: