Indoor Unit
SiBE041025
110
Removal Procedure
4
Disconnect the wire
harnesses from the
terminal board with
pliers.
5
Release the 4 hooks.
Lift up the upper part of
the control PCB and
remove it.
6
The figure shows the
component parts of the
control PCB.
[S6]: swing motor
[S26]: display PCB
[S32]: indoor heat exchanger
thermistor
[S200]: fan motor
[S403]: adaptor PCB (option)
Step
Procedure
Points
(R12060)
(11943)
Control
PCB
Hook
Hook
S32
S200
S24
S26
(R8013)
[S26]
[S6]
[S403]
[S32]
[S200]
Fuse (250 V, 3.15 A)
Содержание J Series
Страница 1: ...SiBE041025 Applied Models Inverter Pair Heat Pump Inverter Pair Wall Mounted Type J Series ...
Страница 11: ...SiBE041025 List of Functions 1 Part 1 List of Functions 1 Functions 2 ...
Страница 13: ...SiBE041025 Specifications 3 Part 2 Specifications 1 Specifications 4 ...
Страница 108: ...Indoor Unit SiBE041025 98 Removal Procedure 5 Remove the horizontal blade Step Procedure Points R11626 ...