Operation example
: Schedule timer based on ON/OFF instruction
When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer if ON
instruction is active. If OFF instruction is active this will have priority
over the setback function. At any time the OFF instruction will have
the highest priority.
1
Schedule timer
2
Setback function
3
When both setback function and schedule timer are
enabled
A
Setback function
B
ON/OFF instruction
t
Time
T
Temperature set point
Room temperature
Leaving water temperature
11.3.10. Programming and consulting the schedule timer
Getting started
Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:
Familiarise yourself with the icons and the buttons. You will need
them when programming. Refer to
of buttons and icons" on page 28
Fill out the form at the very end of this manual. This form can
help you define the required actions for each day.
Take your time to enter all data accurately.
Try to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.
If 2 or more actions are programmed for the same day and at the
same time, only the first programmed action will be executed.
Example:
You can always alter, add or remove the programmed actions
later.
INFORMATION
When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure (if time
is shorter than 2 hours). It is therefore recommended
to leave the auto restart function enabled.
The programmed schedule is time driven. Therefore,
it is essential to set the clock and the day of the week
correctly.
Refer to
"11.3.3. Setting up the controller" on
When the schedule timer is not enabled ( icon not
displayed), schedule timer actions will not be
executed!
The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.
t
18C
40C
40C
18C
A
5:00
23:00
5:00
23:00
2
B
t
9:00
16:00
19C
19C
22C
21C
42C
42C
45C
44C
19C
19C
22C
21C
42C
42C
45C
44C
1
OFF
ON
ON
6:30
0:30
B
t
6:30
9:00
16:00
23:00
19C
19C
22C
21C
42C
42C
45C
44C
19C
19C
22C
21C
42C
42C
45C
44C
3
OFF
ON
ON
18C
40C
40C
18C
Programmed actions
Executed actions
Time
(hour)
Temperature
(°C)
Time
(hour)
Temperature
(°C)
1
18:00
—
OFF
1
06:00
—
21
2
08:00
—
23
2
08:00
—
23
3
06:00
—
21
3
18:00
—
OFF
4
18:00
—
26