4
Set-up and installation
Installation and operating instructions
22
Gas Combi Unit
Floor-standing gas condensing boiler with integrated heat storage
008.1543899_02 – 04/2019 – EN
Fig. 4-10
Minimum distances for installation of the GCU compact
(for dimensions, see
6
Lay the connection lines in such a way that the protective cover
can be removed (
).
4.4.3
Removing the cover and thermal
insulation
1
Unhook the protective cover from the rearward facing holding
burls, lift at the back and remove to the front.
Fig. 4-11
Remove the protective cover
Fig. 4-12
GCU compact without protective cover
CAUTION
The thermal insulation (
, item A) consists of pres-
sure-sensitive EPP moulded parts that can be easily dam-
aged if not handled correctly.
▪ Only remove the thermal insulation in the order stated
below and in the stated directions.
▪ Do not use force.
▪ Do not use tools.
2
Remove the thermal insulation in the following order:
▪ Pull the side insulating element off horizontally (
,
item A).
▪ Pull the rear insulating element off horizontally (
,
item B).
▪ Pull the front insulating element off horizontally (
,
item C).
Fig. 4-13
Removing the top thermal insulation
3
As required:
Remove the bottom thermal insulation in the fol-
lowing order:
▪ Pull the side insulating element off vertically (
, item A).
▪ Pull the rear insulating element off vertically (
, item B).
Fig. 4-14
Removing the bottom thermal insulation
INFORMATION
The thermal insulation is installed in reverse order.