Removal of Indoor Heat Exchanger
Removal Procedure
21
6. Removal of Indoor Heat Exchanger
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
Make sure that the
refrigerant gas is removed
after the pump down
work.
Caution
When removing or
reassembling the indoor heat
exchanger, be sure to wear
gloves or wrap the indoor
heat exchanger with cloth
before proceeding to the
work. (You may be injured by
the fins.)
1
Release the flared
joint of the liquid pipe
and the gas pipe
using 2 wrenches.
2
Remove the piping
fixture.
3
Unfasten the 2 hooks
on the left side of the
indoor heat exchanger.
(R9740)
(R9741)
(R9994)
Left
hook
Right
hook