![Daikin FVXS60HVMA Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/daikin/fvxs60hvma/fvxs60hvma_service-manual_2459616013.webp)
Si06-962
Removal of PCBs
Removal Procedure
11
4. Removal of PCBs
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove of the shield
plate.
1
Pull out the earth wire
from the terminal
board.
2
Release the earth wire.
3
Unfasten the 8 hooks
of the shield plate and
remove it.
(R17109)
Earth
wire
(R9716)
(R9717)
Shield plate