14
English
Remove the
fi
xing screws (2 pcs.), press the tabs (3 positions) using a
fl
athead screwdriver, and remove the upper
7)
casing.
Remove the
fi
xing screw (1 pc.) of both side, press the tabs (2 positions) using a
fl
athead screwdriver, and remove the
8)
side casing on the pipe port cover removing side for the piping.
Remove the pipe port cover for the piping with reference to the slit.
9)
Remove the
pipe port cover.
Frame
Casing
CAUTION
Remove either the left or right pipe port cover depending on which side the piping is located.
•
After removing a pipe port cover, return the casing, air outlet cover, harness for receiver, service lid, and screw covers
10)
to their original positions.