11
|
Configuration
Installer reference guide
46
35M5V1B_35M5V1B
Daikin room air conditioner
4P519439-13N – 2021.03
11 Configuration
11.1 To set a different address
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1
Remove the batteries from the user interface.
2
Cut the address jumper.
a
a
a
Address jumper
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3
Turn the power supply on.
Result:
The flap of the indoor unit will open and close to set the reference position.
4
Press simultaneously
,
and
.
5
Press
and select .
6
Press
to confirm selection.
ON/OFF
a
b
a
Operation lamp
b
Indoor unit ON/OFF switch
7
Press the indoor unit ON/OFF switch while the operation lamp is blinking.
Jumper
Address
Factory set default
1
After cutting jumper
2
INFORMATION
If the setting could NOT be completed while the operation lamp was blinking, repeat
the setting process from the beginning.