background image

2

 | 

User safety instructions

User reference guide

7

FTXTA30C2V1B(W)(B)
Daikin room air conditioner
4P518786-11K – 2023.05

Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be  mixed  with
unsorted  household  waste.  Do  NOT  try  to  dismantle  the  system  yourself:
dismantling  the  system,  treatment  of  the  refrigerant,  of  oil  and  of  other  parts
MUST  be  done  by  an  authorised  installer  and  MUST  comply  with  applicable
legislation.

Units MUST be treated at a specialised treatment facility for reuse, recycling and
recovery.  By  ensuring  this  product  is  disposed  of  correctly,  you  will  help  to
prevent  potential  negative  consequences  for  the  environment  and  human
health. For more information, contact your installer or local authority.

Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted  household
waste. If a chemical symbol is printed beneath the symbol, this chemical symbol
means that the battery contains a heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste batteries MUST be treated at a specialised treatment facility for reuse. By
ensuring  waste  batteries  are  disposed  of  correctly,  you  will  help  to  prevent
potential negative consequences for the environment and human health.

2.2 Instructions for safe operation

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

CAUTION

The  indoor  unit  contains  radio  equipment,  minimum
separation  distance  between  the  radiating  part  of  the
equipment and the user is 10 cm.

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet  or  outlet.  When  the  fan  is  rotating  at  high  speed,  it
will cause injury.

Содержание FTXTA30C2V1BW

Страница 1: ...User reference guide Daikin room air conditioner FTXTA30C2V1BW FTXTA30C2V1BB...

Страница 2: ...djust the airflow rate 23 5 5 Airflow direction 23 5 5 1 To adjust vertical airflow direction 24 5 5 2 To adjust horizontal airflow direction 24 5 5 3 To use 3D airflow direction 24 5 6 Comfort airflo...

Страница 3: ...e NOT system malfunctions 54 8 1 1 Symptom A sound like water flowing is heard 54 8 1 2 Symptom A blowing sound is heard 54 8 1 3 Symptom A ticking sound is heard 54 8 1 4 Symptom A whistling sound is...

Страница 4: ...he box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for...

Страница 5: ...minor or moderate injury NOTICE Indicates a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Expl...

Страница 6: ...physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards...

Страница 7: ...ority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbo...

Страница 8: ...esent Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before resuming operation CAUTION ALWAYS use the wireless remote control or other user in...

Страница 9: ...g materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless WARNING The appliance shall be s...

Страница 10: ...age Splashed detergent on electric components such as motors may cause failure smoke or ignition DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the breaker OFF or pull...

Страница 11: ...t will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may...

Страница 12: ...ser interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface This manual describes only operation with this user interface If a...

Страница 13: ...swing button g Comfort airflow and Intelligent eye operation button h Select button i Clock and open panel push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Fla...

Страница 14: ...door unit receives a signal from the user interface Current temperature setting Airflow rate Automatic Airflow rate Indoor unit quiet Airflow rate High Airflow rate Medium high Airflow rate Medium Air...

Страница 15: ...ithin 500 mm under the infrared signal receiver They may influence reception performance of the wireless remote control 1 Aim the signal transmitter at the infrared signal receiver on the indoor unit...

Страница 16: ...es Fixing the user interface to the wall Inserting the batteries in the user interface Setting the brightness of the user interface display Setting the clock Setting the indoor unit position Turning o...

Страница 17: ...ess remote control on the holder 4 4 The clock setting If the indoor unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock m...

Страница 18: ...5 1 To set the brightness of the indoor unit display 1 Press for at least 2 seconds Result The menu appears on the display is blinking 2 Press 3 Press or to change the setting as follows is blinking B...

Страница 19: ...seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blinks 3 Press to select the menu Result blinks 4 Press or to change the setting...

Страница 20: ...A safety device might stop the operation of the system if the unit runs outside its operation range b Condensation and water dripping might occur if the unit runs outside its operation range 5 2 When...

Страница 21: ...in the room Powerful To cool down or heat up the room quickly ON timer OFF timer To automatically turn ON or OFF the system Weekly timer To automatically turn ON or OFF the system on a weekly basis A...

Страница 22: ...operating Operation mode Automatic Operation mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operati...

Страница 23: ...tem directs the airflow differently depending on the user selection swinging or fixed position It does so by moving horizontal blades flaps or vertical blades louvers Setting Airflow direction Vertica...

Страница 24: ...ppears from the LCD The louvers will stop moving INFORMATION When the unit is installed in a corner of a room the direction of the louvers should be facing away from the wall Efficiency will drop if a...

Страница 25: ...tions Warming up Downward direction Vertical airflow direction INFORMATION If you want to deactivate the Vertical airflow function e g in case there is furniture or another object under the unit refer...

Страница 26: ...ed by 2 C Cooling and drying If the temperature in the room is 30 C the temperature is raised by 2 C 30 C the temperature is raised by 1 C Fan only Decreases airflow rate About the Intelligent eye sen...

Страница 27: ...ration will NOT increase the capacity of the unit if it already operates at maximum capacity 5 7 1 To start stop Powerful operation 1 Press to start Result is displayed on the LCD Powerful operation r...

Страница 28: ...r consumption B Time a Maximum during normal operation b Maximum during Econo operation c Normal operation d Econo operation The diagram is for illustrative purposes only The maximum running current a...

Страница 29: ...are generated and go away inside the unit to ensure safe operation The Streamer discharge may generate a fizzing sound If the airflow becomes weak the Streamer discharge may stop temporarily to preve...

Страница 30: ...e Example The ON timer is set to 13 30 the unit will start operating at 13 30 12 hour countdown OFF ON timer The unit will stop start operating after the set number of hours Example The ON timer is se...

Страница 31: ...timer is set the air conditioner automatically adjusts the temperature setting 0 5 C up in cooling 2 0 C down in heating to prevent excessive cooling heating and ensure a comfortable sleeping temperat...

Страница 32: ...y 1 hour 3 Press or to confirm the setting Result and or and the set time are displayed on the LCD The timer lamp lights up The time displayed on the LCD will automatically count down by 1 hour for ev...

Страница 33: ...o 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operation mode and set temperature OFF OFF OFF OFF setting Only the turn off time ca...

Страница 34: ...step 9 6 Press or to select the time The time can be set between 0 00 23 50 in 10 minute intervals 7 Press Result The time is set and and the temperature blink Note Press to return to the previous sc...

Страница 35: ...to another day The complete reservation of the selected day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day...

Страница 36: ...reservations To delete individual reservations Use this function if you want to delete a single reservation setting 1 Press Result The day of the week and the reservation number are displayed 2 Press...

Страница 37: ...with minimum supported version of Android or iOS specified on app daikineurope com Internet line and communication device such as a modem router etc Wireless LAN access point Installed free ONECTA ap...

Страница 38: ...eless LAN setting menu During setting always aim the wireless remote control at the infrared signal receiver on the unit INFORMATION Make sure operation is stopped before setting the wireless connecti...

Страница 39: ...tedly or until the WPS setting display menu appears 3 Press to confirm the selection Result Beep sound is heard when the unit receives signal 4 Press the WPS button on your communication device e g ro...

Страница 40: ...f the connection was unsuccessful 1 Hold for at least 5 seconds in the default screen Result The confirmation display menu appears 2 Press repeatedly or until the menu appears 3 Hold for at least 2 se...

Страница 41: ...room air conditioner 4P518786 11K 2023 05 3 Hold for at least 2 seconds to confirm the selection Result Beep sound is heard when the unit receives signal Result Communication is OFF 4 Press to exit th...

Страница 42: ...ains or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the d...

Страница 43: ...imum operation User reference guide 43 FTXTA30C2V1B W B Daikin room air conditioner 4P518786 11K 2023 05 Operate the system within the recommended temperature range 26 28 C for cooling and 20 24 C for...

Страница 44: ...the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation...

Страница 45: ...astic components or water leakage Splashed detergent on electric components such as motors may cause failure smoke or ignition DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operatio...

Страница 46: ...will open Note Press and hold again for at least 2 seconds to close the front panel 3 Turn the power supply off 4 Pull down both locks on the back of the front panel 5 Open the front panel until the...

Страница 47: ...Information RoHS compliant non toxic or corrosive There are no specific PPE recommendations Disposal shall comply with government and legal regulations governing the disposal of material Store in the...

Страница 48: ...titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 weeks 7 7 To clean the titanium apatite deodorising filter and the silver particle filter A...

Страница 49: ...he filter from the tabs of the filter frame and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste To or...

Страница 50: ...ase it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 446 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lig...

Страница 51: ...ress and select operation 2 Press and start operation 3 After operation stops turn the breaker OFF 4 Clean the air filters and replace them in their original positions 5 Remove the batteries from the...

Страница 52: ...operly except for the above mentioned cases and none of the above mentioned malfunctions is evident investigate the system in accordance with the following procedures Malfunction Measure If the system...

Страница 53: ...nd windows to prevent wind from coming in Check if the unit operates in Econo or Outdoor unit quiet operation Refer to 5 8 Econo and Outdoor unit quiet operation 428 Check if there is any furniture di...

Страница 54: ...o fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date possibly listed on the warr...

Страница 55: ...em protection 8 1 10 Symptom Airflow rate setting does NOT resume when Comfort airflow is deactivated by ONECTA app If Comfort airflow operation is deactivated by ONECTA app the airflow rate does NOT...

Страница 56: ...ecutive beeps indicate non corresponding codes To cancel the code display hold for 5 seconds The code will also disappear from the display if the button is NOT pressed within 1 minute System Error cod...

Страница 57: ...r wireless LAN connection The following table provides a brief description of how to deal with some problems If none of the following solutions fix the problem go to app daikineurope com for more info...

Страница 58: ...is OK Try resetting to the factory default and repeat the setting See To reset the connection setting to the factory default 440 Displayed indoor outdoor temperature humidity value in Online Controlle...

Страница 59: ...8786 11K 2023 05 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units...

Страница 60: ...ervice to the product Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual spec...

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ...4P518786 11K 2023 05 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: