Indoor Unit Installation Drawings
Intelligent-eye sensor
CAUTION
1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.
30mm or more from ceiling
Front panel
50mm or more
from walls
(on both sides)
Intelligent-eye sensor
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Lift the service lid upward.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Caulk
pipe hole
gap
with putty.
Screws (Field supply)
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
A
Mounting plate
D
E
Remote
controller
holder
Wireless
remote
controller
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
Screws
(Field supply)
B Titanium Apatite Photocatalytic
Air-Purifying Filter
Tabs (upper 3 locations)
Tabs (lower 3 locations)
Air filters
Insert the upper side of the Titanium Apatite
Photocatalytic Air-Purifying Filter into the tabs
(upper 3 locations), push the lower side of the filters
up a little and into the tabs (lower 3 locations).
B