Daikin FTXS09HVJU Скачать руководство пользователя страница 4

3

 

CAUTION

The air conditioner must be grounded to the earth. Improper grounding may result in electric shocks. Do not connect the earth 

• 

grounding wire to a gas pipe, water pipe, lightning rod, or a telephone ground line. Follow all local and state electrical codes.

Do not use this unit for cooling precision instruments, food, plants, animals or works of art.

• 

Never expose little children, plants or animals directly to the air 

fl

 ow.

• 

Do not block air inlets nor outlets. Impaired air 

fl

 ow may result in poor performance or equipment problems.

• 

Do not stand, sit, or place objects on the outdoor unit. To avoid injury, do not remove the fan guard.

• 

Do not place anything under the indoor or outdoor unit that must be kept away from moisture , such as electrical or 

• 

electronic equipment. In certain conditions, moisture in the air may condense and drip.
Check the unit stand and 

fi

 ttings for damage annually.

• 

Do not touch the air inlet and aluminum 

fi

 ns of outdoor unit. It may cause injury and/or damage the heat transfer surface.

• 

This appliance is NOT intended for use by young children or impaired persons without proper supervision.

• 

Young children should be supervised to ensure that they DO NOT play with or near the air 

fl

 ow of this appliance.

• 

Do not pull at the conduit or hang anything on it. Otherwise it will cause 

fi

 re or electric shock.

• 

Do not touch the heat exchanger 

fi

 ns. Improper handling may result in injury.

• 

Do not turn off the power immediately after stopping operation. Always wait at least 

fi

 ve minutes before turning off the 

• 

power. Otherwise, water leakage and trouble may occur.

To avoid personal injury or equipment damage be sure to stop the operation, turn the breaker off or pull out the supply 

• 

cord before cleaning or servicing the unit. NOTE: More than one disconnect may be required to shut off all power.
Do not connect the air conditioner to a power supply different from the one speci

fi

 ed. It may cause improper operation or 

fi

 re.

• 

Depending on the environment, state and local electrical codes, a ground fault circuit interrupter may be required. 

• 

Improper grounding or lack of a ground fault circuit interrupter may result in electrical shock, injuries, or death.
Arrange the drain hose to ensure smooth drainage. Improper drainage may cause water damage to the building, or it’s furnishing.

• 

Depending on the usage environment, water may leak from the air conditioner. If this happens, contact your Daikin Dealer.

• 

The remote controller should be installed in such away that children cannot play with it.

• 

Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit.

• 

Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, 
smoke or 

fi

 re when making contact with electrical parts.

Do not operate the air conditioner with wet hands.

• 

Do not wash the indoor unit with excessive water, only use a slightly wet cloth.

• 

Do not place things such as vessels containing water or anything else on top of the unit. Water may penetrate into the 

• 

unit and degrade electrical insulations, resulting in an electric shock.

Installation site.

To install the air conditioner in the following types of environments, consult the dealer.

 

Places with an oily ambient or where steam or soot occurs.

• 

Salty environment such as coastal areas.

• 

Places where sul

fi

 de gas occurs such as hot springs.

• 

Places where snow may block the outdoor unit.The drain from the outdoor unit must be discharged to a place of good drainage.

• 

Consider nuisance to your neighbours from noises.

For installation, choose a place as described below.

 

A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.

• 

A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.

• 

Electrical work.

For power supply, be sure to use a separate power circuit dedicated to the air conditioner.

• 

System relocation.

Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for 

• 

moving or remodeling. 

01_EN_3P232717-1C.indd   3

01_EN_3P232717-1C.indd   3

12/22/2008   2:51:30 PM

12/22/2008   2:51:30 PM

Содержание FTXS09HVJU

Страница 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS09HVJU FTXS12HVJU...

Страница 2: ...ore Operation 8 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 INTELLIGENT EYE Operation 13 POWERFUL Operation 15 OUTDOOR UNIT QUIET Operation 16 HOME LEAVE Operation...

Страница 3: ...mediately for instructions Do not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death If equipment utilizing a burner is use...

Страница 4: ...nvironment state and local electrical codes a ground fault circuit interrupter may be required Improper grounding or lack of a ground fault circuit interrupter may result in electrical shock injuries...

Страница 5: ...lter with photocatalytic deodorizing function Air filter Indoor unit ON OFF switch Push this switch once to start operation Push once again to stop it The operation mode refer to the following table M...

Страница 6: ...f the outdoor unit may differ from some models Refrigerant piping and inter unit cable Earth terminal It is inside of this cover Drain hose Air inlet Back and side Air outlet Air filter Air purifying...

Страница 7: ...The maximum distance for communication is approximately 23 ft 7m FAN setting button It selects the airflow rate setting Page 11 POWERFUL button POWERFUL operation Page 15 Display LCD It displays the c...

Страница 8: ...T EYE operetion Page 13 ON TIMER button Page 20 CLOCK button Page 9 QUIET button OUTDOOR UNIT QUIET operation Page 16 OFF TIMER button Page 19 TIMER CANCEL button It cancels the timer setting Page 19...

Страница 9: ...The attached batteries are provided for the initial use of the system The usable period of the batteries may be short depending on the manufactured date of the air conditioner About remote controller...

Страница 10: ...tion Under 0 F and over 115 F outdoor temperature See Note 2 for 0 F to 14 F operation Condensation may occur on the indoor unit and drip HEAT Outdoor temperature 5 to 64 F 15 to 18 C Indoor temperatu...

Страница 11: ...DRY COOL HEAT FAN Press 2 is displayed on the LCD The OPERATION lamp lights up Control panel ON OFF To stop operation Press again disappears from the LCD Then OPERATION lamp goes off To change the tem...

Страница 12: ...operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does...

Страница 13: ...button is selected the flaps swinging range depends on the operation mode See the figure Three Dimensional 3 D Airflow Using three dimensional airflow circulates cold air which tends to collected at t...

Страница 14: ...from the LCD EX Somebody back in the room Back to normal operation The air conditioner will return to normal operation when the sensor detects the movement of people again When somebody in the room N...

Страница 15: ...80 50 16ft 5m 50 16ft 5m Vertical angle 80 Side View Horizontal angle 100 Top View Sensor may not detect moving objects further than 16ft 5m away Check the application range Sensor detection sensitiv...

Страница 16: ...pressed last POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD In COOL and HEAT mode To...

Страница 17: ...IET operation This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time Prior...

Страница 18: ...eration for the first time please set the temperature and airflow rate for HOME LEAVE operation Record your preferred temperature and airflow rate Initial setting Selectable range Temperature Airflow...

Страница 19: ...when going to bed The unit will maintain the temperature in the room at a comfortable level while you sleep When you enter the living room in the morning the temperature will be just right Disengaging...

Страница 20: ...hanges the setting rapidly Press 3 again The TIMER lamp lights up Control panel ON OFF To cancel OFF TIMER Operation Press The TIMER lamp goes off NOTE When TIMER is set the present time is not displa...

Страница 21: ...wn either button changes the setting rapidly Press 3 again The TIMER lamp lights up Control panel ON OFF To cancel ON TIMER Operation Press The TIMER lamp goes off To combine ON TIMER and OFF TIMER A...

Страница 22: ...t up in the shade after washing Attach the front panel 4 Set the 3 keys of the front panel into the slots and push them in all the way Close the front panel slowly and push the panel at the 3 points 1...

Страница 23: ...Clean or replace each filter 4 See figure Set the air filter and the Air purifying filter with photocatalytic 5 deodorizing function as they were and close the front panel Insert claws of the filters...

Страница 24: ...deodorizing function can be renewed by washing it with water once every 6 months We recommend replacing it once every 3 years Maintenance Vacuum dusts and soak in warm water or water for about 10 to 1...

Страница 25: ...ng the Air purifying filter with photocatalytic deodorizing function CHECK Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the ai...

Страница 26: ...the cold airflow during cooling operation This is because the air in the room is cooled by the heat exchanger and becomes mist during defrost operation The indoor unit gives out odour This happens whe...

Страница 27: ...priately Operation stops suddenly OPERATION lamp flashes Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or t...

Страница 28: ...e earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the...

Страница 29: ...PERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OPERATION HALT DUE TO DETE...

Страница 30: ...3P232717 1C M08B052A 0901 HT Two dimensional bar code is a code for manufacturing...

Отзывы: