![Daikin FTXR50EV1B9 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/daikin/ftxr50ev1b9/ftxr50ev1b9_operation-manual_3431898016.webp)
15
■
English
MOLD PROOF Operation
Dries the inside of the unit to prevent mold and odors.
■
Movement during MOLD PROOF operation
■
Auto operation
(approximately once every 2 weeks)
If the unit is set to “MOLD PROOF ON”, the MOLD PROOF operation will start automat-
ically after the unit has been run in “SARARA” DRYING or COOLING mode, depending
on the amount of time the unit has been run (approximately once every 2 weeks).
(page 14.) The default is set to “MOLD PROOF OFF”.
■
Manual operation
1. Hold “
” for about 2 seconds while the unit is not
running.
•
The front panel and horizontal louver will open.
•
The MOLD PROOF operation runs for 2-3 hours, changing the color of the multi-
colored indicator lamp of the unit.
■
If you want to stop MOLD PROOF operation
during operation
2. Hold “
” (again) for about 2 seconds.
•
The front panel and horizontal louver will close.
•
The multi-colored indicator of the unit will go off.
Stop COOLING,
DRY COOLING,
and “SARARA”
DRYING
operations
PRE-
DRYING
[FAN]
HEATING
with the
internal
fan off
FAN
HEATING
<Color of multi-colored indicator lamp>
Operation complete
Blinks alternately.
Purple
Blue
Blinks alternately.
Blue
Light blue
Blinks alternately.
Light blue
White
White
(In case of manual operation)
1, 2
The MOLD PROOF operation will start.
The display will return to normal.
NOTE
■
Note on MOLD PROOF operation
•
Dries out the interior of the air conditioner using FAN and HEATING operation mode to exhaust humidity to the outdoor. This prevents mold
and odor growth. This function is not designed to remove existing dust or mold.
•
During MOLD PROOF operation, the room temperature may rise and humidity from the machine may be sent into the room. Some odors
may be noticed, too. Use when there is no one in the room.
•
The mode may not be used if the outside temperature or humidity is very high.
•
The exhausting operation may not be run depending on the outdoor temperature.
•
MOLD PROOF operation mode is not available if the unit is shut off using the COUNTDOWN OFF TIMER. MOLD PROOF operation mode
only comes on automatically if the unit has been stopped using the operation/stop switch on the remote controller or the main unit.
•
If MOLD PROOF operation is stopped during AUTO mode, the operation comes on automatically next time, depending on the amount of
time the unit had been operating. To cancel the AUTO mode, set to “MOLD PROOF OFF”. (page 14.)
01_EN_3P190650-1D.fm Page 15 Tuesday, March 6, 2007 6:26 PM