Table of contents

Installation manual

4

FTXP20~3 ATXP20~35N5V1B

Daikin room air conditioner

3P650253-9H – 2022.10

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 Specific installer safety instructions

4

3 About the box

6

3.1

Indoor unit .................................................................................

6

3.1.1

To remove the accessories from the indoor unit.........

6

4 About the unit

6

4.1

System layout ............................................................................

6

4.2

Operation range ........................................................................

7

5 Unit installation

7

5.1

Preparing the installation site ....................................................

7

5.1.1

Installation site requirements of the indoor unit ..........

7

5.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

7

5.2

Opening the indoor unit .............................................................

7

5.2.1

To remove the front panel...........................................

7

5.2.2

To re-install the front panel .........................................

8

5.2.3

To remove the front grille ............................................

8

5.2.4

To re-install the front grille ..........................................

8

5.2.5

To remove the electrical wiring box cover...................

8

5.2.6

To open the service cover...........................................

8

5.3

Mounting the indoor unit............................................................

8

5.3.1

To install the mounting plate .......................................

8

5.3.2

To drill a wall hole .......................................................

9

5.3.3

To remove the pipe port cover ....................................

9

5.3.4

To provide drainage ....................................................

9

6 Piping installation

10

6.1

Preparing refrigerant piping .......................................................

10

6.1.1

Refrigerant piping requirements.................................. 10

6.1.2

Refrigerant piping insulation ....................................... 11

6.2

Connecting the refrigerant piping ..............................................

11

6.2.1

Guidelines when connecting the refrigerant piping ..... 11

6.2.2

To connect the refrigerant piping to the indoor unit .... 11

6.3

Checking the refrigerant piping .................................................

11

6.3.1

To check for leaks....................................................... 11

6.3.2

To perform vacuum drying .......................................... 11

7 Electrical installation

12

7.1

Specifications of standard wiring components ..........................

12

7.2

To connect the electrical wiring to the indoor unit .....................

12

8 Finishing the indoor unit installation

13

8.1

To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................

13

8.2

To pass the pipes through the wall hole....................................

13

8.3

To fix the unit on the mounting plate .........................................

13

9 Configuration

13

9.1

To set a different channel of the indoor unit infrared signal
receiver......................................................................................

13

10 Commissioning

14

10.1

Checklist before commissioning ................................................

14

10.2

To perform a test run .................................................................

14

10.2.1

To perform a test run in winter season ....................... 14

11 Disposal

15

12 Technical data

16

12.1

Wiring diagram ..........................................................................

16

12.1.1

Unified wiring diagram legend..................................... 16

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

Unit installation (see 

"5 Unit installation"

 [

4

 7])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

Содержание FTXP20N5V1B

Страница 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXP20N5V1B FTXP25N5V1B FTXP35N5V1B ATXP20N5V1B ATXP25N5V1B ATXP35N5V1B...

Страница 2: ...s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu e sa v robk...

Страница 3: ...7 1206 Radio Equipment Regulations 2017 following the provisions of BS EN 60335 2 40 2003 A13 2012 BS EN IEC 62311 2020 BS EN IEC 55014 1 2021 BS EN IEC 55014 2 2021 BS EN IEC 61000 3 2 2019 A1 2021 B...

Страница 4: ...fferent channel of the indoor unit infrared signal receiver 13 10 Commissioning 14 10 1 Checklist before commissioning 14 10 2 To perform a test run 14 10 2 1 To perform a test run in winter season 14...

Страница 5: ...ill be sucked in This will cause abnormal pressure in the refrigeration cycle which may result in equipment damage and even injury CAUTION Incomplete flaring may cause refrigerant gas leakage Do NOT r...

Страница 6: ...DANGER RISK OF ELECTROCUTION Disconnect the power supply for more than 10 minutes and measure the voltage at the terminals of main circuit capacitors or electrical components before servicing The vol...

Страница 7: ...fety precaution 5 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is less than 70 dBA Air flow Make sure nothing blocks the air flow Drainage Make sure conde...

Страница 8: ...then mount the front panel 5 2 5 To remove the electrical wiring box cover 1 Remove the front grille 2 Remove 1 screw from the electrical wiring box 3 Open the electrical wiring box cover by pulling t...

Страница 9: ...ppers to remove the pipe port cover as this would damage the front grille 5 3 4 To provide drainage Make sure condensation water can be evacuated properly This involves General guidelines Connecting t...

Страница 10: ...left side and do not forget to tighten it with the fixing screw otherwise water leakage may occur a b a b a Insulation fixing screw b Drain hose 4 Attach the drain hose to the refrigerant piping bott...

Страница 11: ...it using flare connections 2 Insulate the refrigerant piping interconnection cable and drain hose on the indoor unit as follows c a b f d g e a Gas pipe b Gas pipe insulation c Interconnection cable d...

Страница 12: ...cable for 220 240 V Recommended field fuse 20 A Earth leakage circuit breaker Must comply with applicable legislation 7 2 To connect the electrical wiring to the indoor unit WARNING Provide adequate m...

Страница 13: ...the bottom frame or the front grille 2 Pass the drain hose and refrigerant piping through the wall hole and seal the gap with a putty 8 3 To fix the unit on the mounting plate 1 Set the indoor unit on...

Страница 14: ...e refrigerant pipes gas and liquid are thermally insulated Drainage Make sure drainage flows smoothly Possible consequence Condensate water might drip The system is properly earthed and the earth term...

Страница 15: ...operation press INFORMATION Some of the functions CANNOT be used in the test run operation mode If a power failure occurs during operation the system automatically restarts immediately after power is...

Страница 16: ...AC CN E HA HE HL HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Conne...

Страница 17: ...FTXP20 35N5V1B ATXP20 35N5V1B Daikin room air conditioner 3P650253 9H 2022 10 Symbol Meaning X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve c...

Страница 18: ......

Страница 19: ......

Страница 20: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P650253 9H 2022 10 Copyright 20...

Отзывы: