manualshive.com logo in svg
background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXM20UVMZ
FTXM25UVMZ
FTXM35UVMZ
FTXM46UVMZ

00_CV_3P552666-5B.indd   1

07-May-19   12:54:04 PM

Содержание FTXM20UVMZ

Страница 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM20UVMZ FTXM25UVMZ FTXM35UVMZ FTXM46UVMZ 00_CV_3P552666 5B indd 1 07 May 19 12 54 04 PM...

Страница 2: ...in a quiet neighbourhood Page 18 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the...

Страница 3: ...Parts 5 Preparation Before Operation 9 Basic Operation AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Rate 12 Adjusting the Airflow Direction 13 Useful Functions COMFORT AIRFLOW Operation...

Страница 4: ...y result due to contact with the air conditioner s high speed fan blades Do not attempt to repair dismantle reinstall or modify the air conditioner yourself as this may result in water leakage electri...

Страница 5: ...or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be broken and the panel ma...

Страница 6: ...operation Press once again to stop it For the operation mode setting refer to the following table Mode Temperature setting Airflow rate AUTO 25 0 C AUTO This switch can be used when the remote control...

Страница 7: ...unit wire Drain hose Air outlet Air inlet back and side Earth terminal inside For 46 class For 20 25 35 class Refrigerant pipes and inter unit wire Earth terminal inside Drain hose Air outlet Air inl...

Страница 8: ...out 7m FAN setting button Selects the airflow rate setting Page 12 POWERFUL button POWERFUL operation Page 17 Model name ARC466A26 Display LCD Displays the current settings In this illustration each s...

Страница 9: ...CEL button Cancels the timer setting Page 19 20 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UN...

Страница 10: ...sing the product for long periods of time The standard replacement time is 1 year Both batteries should be replaced at the same time Be sure to replace them with new size AAA LR03 alkaline batteries W...

Страница 11: ...esent time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks NOTE Note on setting the clock If t...

Страница 12: ...he button changes the temperature by 0 5 C COOL operation HEAT operation AUTO operation DRY or FAN operation 18 0 32 0 C 10 0 30 0 C 18 0 30 0 C The temperature setting cannot be changed AUTO DRY COOL...

Страница 13: ...n while it is not operating You can adjust the airflow rate to increase your comfort To adjust the airflow rate setting Press Each pressing of changes the airflow rate setting in sequence AUTO Indoor...

Страница 14: ...and appear on the LCD The flap and louvres move in turn To cancel 3 D airflow press either or again The flap or louvres will stop moving To set the flap or louvres at the desired position This functi...

Страница 15: ...is pressed last COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL operation and in the downward direction while in HEAT operation which will provide a comfortable...

Страница 16: ...LCD The INTELLIGENT EYE lamp lights green Display blank No Setting Do not blow directly on people Blow directly on people When the flap horizontal blade is swinging selecting any of the modes above w...

Страница 17: ...sensor people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit If there are people close to the front side of the indoor unit or in both areas...

Страница 18: ...se the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the cooling heating effect the...

Страница 19: ...is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level...

Страница 20: ...ecreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and...

Страница 21: ...3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes...

Страница 22: ...F TIMER Page 19 20 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON OFF TIMER and COUNT UP DO...

Страница 23: ...for Monday Page 25 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 23 8...

Страница 24: ...day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set...

Страница 25: ...ation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 25 NOTE Notes on WEE...

Страница 26: ...he selected day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selecte...

Страница 27: ...Proceed to Setting mode STEP 4 Page 23 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To deactivate WEEKLY TIMER...

Страница 28: ...rvations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press The day of the week and t...

Страница 29: ...sh the filter Once every 2 weeks Page 29 Front panel Wipe it with a soft damp cloth Only neutral detergent may be used If dirty Titanium apatite deodorizing filter included with the air conditioner an...

Страница 30: ...water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm...

Страница 31: ...r about 10 to 15 minutes if very dirty 3 2 After washing shake off remaining water and let them dry in the shade This filter can be renewed by washing it with water once every 6 months and we recommen...

Страница 32: ...ke out the batteries from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resultin...

Страница 33: ...changes Whistling sound This sound is generated when refrigerant flows during defrosting operation Clicking sound during operation or idle time This sound is generated when the refrigerant control va...

Страница 34: ...t the system While the air conditioner is not in operation When the outdoor temperature is high the outdoor unit fan may start rotating to protect the system The room does not cool down warm up Case D...

Страница 35: ...heating or lead to equipment failure Even when the LCD is blinking the OFF button remains functional Other electric devices start operating If the remote controller activates other electric devices m...

Страница 36: ...ed An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There...

Страница 37: ...FAN MOTOR FAULT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COM...

Страница 38: ...37 MEMO 01_EN_3P552666 5B indd 37 3 05 2019 3 10 50 PM...

Страница 39: ...01_EN_3P552666 5B indd 38 3 05 2019 3 10 50 PM...

Страница 40: ...The two dimensional bar code is a manufacturing code Quick Reference MODE On Off FAN Temp Mode Swing 3P552666 5B M19N035 1905 HT 00_CV_3P552666 5B indd 2 07 May 19 12 54 08 PM...

Отзывы: