POWERFUL Operation

POWERFUL operation quickly maximizes the cooling (heating) effect in any 

operation mode. You can get the maximum capacity.

 

„

To start POWERFUL operation

Press 

 during operation.

• 

POWERFUL operation ends in 20 minutes.  Then the system automatically operates 
again with the previous settings which were used before POWERFUL operation.

• “ 

 ” is displayed on the LCD.

 

„

To cancel POWERFUL operation

Press 

 again.

• “ 

 ” disappears from the LCD.

[Example]

 

„

Normal operation

• 

When you want to get the 

cooling effect quickly, start 

the POWERFUL operation.

 

„

POWERFUL operation

• 

POWERFUL operation will 

work for 20 minutes.

 

„

Back to normal 

operation

NOTE

 

„

Notes on POWERFUL operation

• 

When using POWERFUL operation, there are some functions which are not available.

• 

POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW or OUTDOOR UNIT QUIET operation.

 

Priority is given to the function of whichever button is pressed last.

• 

POWERFUL operation can only be set when the unit is running. Pressing 

 causes the settings to be canceled, and “   ” disappears 

from the LCD.

• 

POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum 
capacity demonstrated.

• 

In COOL and HEAT operation

 

To maximize the cooling (heating) effect, the capacity of outdoor unit is increased and the airflow rate is fixed to the maximum setting.

 

The temperature and airflow settings are not variable.

• 

In DRY operation

 

The temperature setting is lowered by 2.5°C and the airflow rate is slightly increased.

• 

In FAN operation

 

The airflow rate is fixed to the maximum setting.

• 

In AUTO operation 

To maximize the cooling (heating) effect, the capacity of outdoor unit is increased and the airflow rate is fixed to the maximum setting.

• 

When using priority room setting

 

See “

Note for Multi System

”. 

 Page 29

Содержание FTXG20LV1BW

Страница 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXG20LV1BW FTXG25LV1BW FTXG35LV1BW FTXG50LV1BW FTXG20LV1BS FTXG25LV1BS FTXG35LV1BS FTXG50LV1BS...

Страница 2: ...e noise level of the outdoor unit This function is useful when you need to consider the noise for your neighbourhood Page 19 INTELLIGENT EYE The INTELLIGENT EYE sensor detects the human movement in a...

Страница 3: ...eration 9 Operation AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Direction and Rate 13 COMFORT AIRFLOW INTELLIGENT EYE Operation 15 POWERFUL Operation 18 ECONO OUTDOOR UNIT QUIET Operatio...

Страница 4: ...oving or repairing Using other refrigerants may cause trouble or damage to the unit and personal injury To avoid electric shocks do not operate with wet hands Beware of fire in case of refrigerant lea...

Страница 5: ...cified power supply circuit Power supplies other than the one specified may result in electric shocks overheating and fires Arrange the drain hose to ensure smooth drainage Imperfect drainage may caus...

Страница 6: ...g refer to the following table Mode Temperature setting Airflow rate AUTO 25 C AUTO This switch can be used when the remote controller is missing TIMER lamp When operation by timer has been set the mu...

Страница 7: ...iffer from some models Open the upper front panel Air filter Titanium apatite photocatalytic air purifying filter Refrigerant piping and inter unit wiring Earth terminal It is inside of this cover Dra...

Страница 8: ...the signal receiver Such obstacles if any may have an adverse influence on the reception performance of the receiver and the reception distance may be shortened FAN setting button It selects the airf...

Страница 9: ...Page 22 CLOCK button Page 10 Lamp brightness setting button Page 9 COMFORT SENSOR button COMFORT AIRFLOW and INTELLIGENT EYE operation Page 15 OFF TIMER button NIGHT SET mode Page 21 TIMER CANCEL but...

Страница 10: ...teries out The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries wi...

Страница 11: ...e power is turned on the flaps of the indoor unit open and close once to set the reference position To set the clock 1 Press is displayed on the LCD and blink 2 Press to set the current day of the wee...

Страница 12: ...he air conditioner The heat pump system heats the room by circulating hot air around all parts of the room After the start of HEAT operation it takes some time before the room gets warmer In HEAT oper...

Страница 13: ...s a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn off the circuit breaker Use the ai...

Страница 14: ...e louvres vertical blades will begin to swing The 3 D airflow direction Press and and are displayed on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps...

Страница 15: ...er limit Upper limit COMFORT AIRFLOW Stop operation 50 COOL DRY and FAN operation Note on the angles of the flaps Using 3 D airflow circulates cold air which tends to collect at the bottom of the room...

Страница 16: ...etected in the areas Use the INTELLIGENT EYE operation in combination with the COMFORT AIRFLOW operation The air conditioner will go into energy saving mode after 20 minutes The airflow direction may...

Страница 17: ...e human movements are detected To cancel operation Press and select blank on the LCD The INTELLIGENT EYE lamp goes off Display Operation mode Explanation COMFORT AIRFLOW The flaps will adjust the airf...

Страница 18: ...f they are close to the front side of the indoor unit If there are people close to the front side of the indoor unit or in both areas it is recommended to use the COMFORT AIRFLOW and INTELLIGENT EYE o...

Страница 19: ...AIRFLOW or OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing causes the settings t...

Страница 20: ...ircuit breaker may trip if the air conditioner operates with its maximum capacity The maximum power consumption of the air conditioner is limited by using ECONO operation The circuit breaker will hard...

Страница 21: ...ready low ECONO operation will not drop the power consumption Notes on OUTDOOR UNIT QUIET operation If using a multi system the OUTDOOR UNIT QUIET operation will work only when this function is set on...

Страница 22: ...time are displayed on the LCD The multi monitor lamp blinks twice The TIMER lamp periodically lights orange Page 5 Display To cancel OFF TIMER operation Press and setting time disappear from the LCD a...

Страница 23: ...y 3 Press again and setting time are displayed on the LCD The multi monitor lamp blinks twice The TIMER lamp periodically lights orange Page 5 Display To cancel ON TIMER operation Press and setting ti...

Страница 24: ...ttings are the same as those for Monday Page 26 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to progra...

Страница 25: ...to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4...

Страница 26: ...ng the OFF TIMER 7 Press The time will be set and the temperature blink 8 Press to select the desired temperature The temperature can be set between 10 C and 32 C COOL or AUTO The unit operates at 18...

Страница 27: ...to direct the remote controller toward the indoor unit and check for a receiving tone and flashing the multi monitor lamp The reservation will be copied to the selected day of the week The whole rese...

Страница 28: ...elect the reservation number and press The mode is switched to setting mode Go to setting mode step 2 Page 24 3 Press to exit confirming mode To deactivate WEEKLY TIMER operation Press while is displa...

Страница 29: ...rvation will be deleted 6 Press If there are still other reservations WEEKLY TIMER operation will be activated The reservations for each day of the week This function can be used for deleting reservat...

Страница 30: ...on standby and the multi monitor lamp will flash With the priority room setting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mo...

Страница 31: ...d in room A while operating the following modes in room B C and D Operation mode in room B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN Current oper...

Страница 32: ...ws Hot water above 40 C Benzine gasoline thinner other volatile oils Polishing compound Scrubbing brushes other hard stuff CAUTION Before cleaning be sure to stop the operation and turn off the circui...

Страница 33: ...to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the shade Be sure to remove the...

Страница 34: ...e photocatalytic air purifying filter When attaching the filter check that the filter is set in the tabs Tabs Dispose of the old filter as non flammable waste 3 Set the filters as they were and close...

Страница 35: ...rom the remote controller When a multi outdoor unit is connected make sure the HEAT operation is not used at the other room before you use the FAN operation Page 29 We recommend periodical maintenance...

Страница 36: ...nits in other rooms are in operation Blowing sound This sound is generated when the flow of the refrigerant in the air conditioner is switched over Ticking sound This sound is generated when the size...

Страница 37: ...utlet of the indoor and the outdoor units Turn off the circuit breaker and take all obstacles away Then turn it on again and try operating the air conditioner with the remote controller If the lamp st...

Страница 38: ...new size AAA LR03 alkaline For details refer to To set the batteries of this manual Page 9 The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor...

Страница 39: ...lly resumes operation in about 3 minutes You should just wait for a while Lightning If lightning may strike the neighbouring area stop operation and turn off the circuit breaker for system protection...

Страница 40: ...DETECTION U4 SIGNAL TRANSMISSION ERROR BETWEEN INDOOR AND OUTDOOR UNIT INDOOR UNIT A1 INDOOR UNIT PCB ABNORMALITY A5 FREEZE UP PROTECTION OR HEATING PEAK CUT CONTROL A6 FAN MOTOR DC MOTOR ABNORMALITY...

Страница 41: ...OVERCURRENT REFRIGERANT SHORTAGE LOW VOLTAGE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE LOSS REVERSING SOLENOID VALVE SWITCHING FAILURE FAN MOTOR FAULT NOTE 1 POWER SUPPLY FAULT OR NOTE 2 NOTE The LED5 is...

Страница 42: ...3P357704 1B 2014 08 Quick Reference Copyright 2014 Daikin...

Отзывы: