SiBE04-101
Checks
Service Diagnosis
119
5. Checks
5.1
How to Check
5.1.1
Thermistor Resistance Check
Check No.1
Remove the connectors of the thermistors on the PCB, and measure the resistance of each thermistor
using tester.
The relationship between normal temperature and resistance is shown in the graph and the table below.
Thermistor R25˚C=20k
Ω
B=3950
Temperature (˚C)
-20
211.0 (k
Ω
)
-15
150
-10
116.5
-5
88
0
67.2
5
51.9
10
40
15
31.8
20
25
25
20
30
16
35
13
40
10.6
45
8.7
50
7.2
SiBE04-101.book Page 119 Monday, October 15, 2001 3:08 PM