SiBE04-101
Troubleshooting
Service Diagnosis
99
4.12
Faulty Indoor / Outdoor Power Supply Specification
Remote Controller
Display
UA
Indoor unit LED
Display
Method of
Malfunction
Detection
The indoor/outdoor unit data communication signal is used to detect different power specifications
(connection of indoor power receiving unit and outdoor power receiving unit).
Malfunction
Decision
Conditions
When the indoor power receiving unit is connected to the outdoor power receiving unit.
Supposed Causes
Connection of improper models
Installation of wrong PCB
Faulty PCB
Troubleshooting
Check the PCB No. (such as
2P01234) on the parts list.
Check the model names of the
indoor and outdoor units.
YES
Connect proper models.
Replace the PCB with the
specified type.
Replace the indoor unit PCB.
Is the combination
of indoor/outdoor units
correct?
NO
YES
Is the combination correct?
NO
(R1174)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
SiBE04-101.book Page 99 Monday, October 15, 2001 3:08 PM