5 Installation
Installation manual
5
FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
3P482320-7P – 2019.10
1
Open the front panel. Refer to
"5.1.1 To open the front
panel"
[
4
4].
2
Remove the service cover. Refer to
"5.1.4 To open the service
cover"
[
4
4].
3
Remove the wire harness from the wire clamp and the
connector.
4
Remove the flap by pushing it to the left side and towards you.
5
Remove the 2 screw covers using a long flat plate such as a
ruler wrapped in a cloth and remove 2 screws.
c
d
b
a
a
Connector
b
Wire clamp
c
Screw cover
d
Long flat plate wrapped in a cloth
6
Push the front grille up and then towards the mounting plate to
remove the front grille from the 3 hooks.
a
a
Hook
Prerequisite: If working space is limited.
7
Insert a flat screwdriver next to the hooks.
8
Pull the front grille up using the flat screwdriver and push
towards the mounting plate.
b
a
a
Hook
b
Flat screwdriver
5.1.6
To re-install the front grille
1
Install the front grille and firmly engage the 3 upper hooks.
2
Tighten the 2 screws and put the 2 screw covers back.
3
Re-install the flap.
4
Insert the wire harness back into the connector and secure it
with the wire clamp.
5
Close the front panel. Refer to
"5.1.2 To close the front
panel"
[
4
4].
5.1.7
To remove the electrical wiring box cover
1
Remove the front grille.
2
Remove 1 screw from the electrical wiring box.
3
Open the electrical wiring box cover by pulling it to the front.
4
Remove the electrical wiring box cover from the 2 rear hooks.
1
2
b
a
c
c
a
Screw
b
Electrical wiring box
c
Rear hook
5
To re-install the cover, first attach the electrical wiring box to the
hooks, close the electrical wiring box, and re-install the screw.
5.2
Installing the indoor unit
5.2.1
To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
Содержание FTXA25BB/RXA25A
Страница 1: ...Daikin Stylish FTXA25BB RXA25A...
Страница 6: ......
Страница 12: ......
Страница 15: ...3P482320 7P 2019 10 Copyright 2017 Daikin...
Страница 16: ......